Ultrasonic Conductivity Test Pen

The ultrasonic conductivity test pen measures the liquid's ability to conduct electric current by emitting ultrasonic waves, utilizing the propagation characteristics of sound waves in conductive media to calculate conductivity values. It is used for rapid on-site detection of ion concentrations in liquids such as coatings and inks, guiding adjustments in production processes.
Selection
When selecting, consider that the measurement range covers the conductivity range of the sample to be tested, the probe material's corrosion resistance matches the liquid properties, the temperature compensation function suits the operating environment, the calibration method is simple and convenient, and the device's portability and battery life meet the needs of the usage scenario.

Terms

Standards

Instruments

With conductivity 0~ 19.99mS/cm Measurement range, accuracy +/- 1.0%, support TDS conversion factor and temperature compensation settings. Platinum-plated black ElectRode reduces Polarization effect, IP67 Protection Rating is suitable for use in a variety of environments.

$ 155.00

Combined ElectRode can simultaneously measure pH, conductivity, TDS, salinity and temperature, support one-button switching paraMeters; Conductivity Detector ElectRode platinum black to reduce Polarization effect, accuracy of +/- 0.01pH; with automatic temperature compensation and IP67 dustproof and waterproof design.

$ 213.00

Platinum Sensor ensures fast and stable measurement, supports 1-3 point calibrate and 0.1-1 adjustable TDS conversion factor, with automatic temperature compensation and end point locking function, Measurement range covers 0-20mS/cm conductivity and 0-10ppt salinity.

$ 165.00

Measurement range 0~ 199μS/cm, automatic temperature compensation 0~ 50 ℃, waterproof shell design, ElectRode replaceable, easy to carry and operate.

$ 101.00

Platinum ElectRode ensures fast and stable measurement, supports 1-3 point calibrating and automatic temperature compensation, salinity Measurement range 0-80ppt, conductivity covers 100μS/cm to 200mS/cm, with automatic end lock and fully waterproof design.

$ 167.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Support conductivity, TDS, salinity and resistivity Multi-ParaMeter measurement, conductivity range 0.000 μS/cm to 1000mS/cm, with intelligent end point determination and automatic temperature compensation function.

$ 741.00

Measurement range 0~ 19.99mS/cm, resolution 1uS, automatic temperature compensation and temperature display, ElectRode replaceable, waterproof housing design, easy to carry operation.

$ 107.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.

$ 102.00

With microwave and ultrasonic coordinated control function, 250ml container capacity with 1800W adjustable ultrasonic Power, infrared temperature sensor and magnetic stirring system, support a variety of reaction modes to expand applications.

$ 17178.00

Suitable for low conductivity water samples with conductivity above 100 µS/cm, using polymer liquid junction design, pH Measurement range 0-11pH, Temperature Measurement range 0-80 ℃, no need to add liquid reference system.

$ 208.00

Plastic film surface tension can be accurately tested, suitable for a variety of printing composite process, can customize ink Color and pen shape, specifications include 10ml to 500ml bottles.

$ 87.00

Measurement range 0-2μS/cm with Mini-DIN 8 core connector for accurate detection of low conductivity solutions.

$ 199.00

Equipped with microwave and ultrasonic synergy function, 2000ml large-capacity reactor and 1800W ultrasonic power, support platinum resistance accurate temperature measurement and magnetic stirring, and realize multi-mode chemical reaction control.

$ 15887.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
To determine if an ultrasonic cleaner cleans effectively, first understand the two key parameters: frequency and power.
This article mainly discusses how to achieve thorough cleaning with an ultrasonic cleaner, emphasizing that the key factors are frequency and power. The frequency determines the size and penetrating ability of the bubbles generated during cleaning, while the power provides the necessary energy for the cleaning process.