Measurement range 0~ +/- 1999mV, resolution 1mV, temperature measurement 0~ 60 ℃, standard ORP and temperature ElectRode, fast reaction Stability, suitable for solution temperature measurement in the range of 5~ 60 ℃.
Microprocessor control with 0.1mV high resolution design, support pH, mV, ORP, temperature Multi-ParaMeter measurement, with automatic identification calibrate and ElectRode diagnostic function, Measurement range covering -5.00~ 20.00pH.
With relative and absolute mV measurement function, Measurement range -999~ 999mV, accuracy +/- 2mV, support automatic end point locking and 1 point offset calibrating, fully waterproof design for use in harsh environments.
Measurement accuracy of 0.2mV and +/- 2000.0mV range, support for automatic end point locking and timed interval readings, built-in calibrated reminders and password protection to ensure data accuracy and operational safety.
Glass composite structure can be filled, ORP Measurement range up to +/- 2000mV, temperature range -5 to 70 ℃, equipped with platinum needle temperature sensor, supports routine laboratory and titration applications.
Measurement accuracy of +/- 0.05pH, resolution of 0.01pH, pH and mV can be detected at the same time, built-in battery supports 10-15 hours of battery life, easy to operate, stable and reliable.
Measurement accuracy of +/- 0.01pH, resolution of 0.01pH/1mV, support 0-60 ℃ Temperature Measurement range, equipped with positioning, slope, temperature adjustment knob for calibrating operation.
The calibrated value is 470mV, the capacity is 500mL, and the tamper-proof sealing design is adopted to ensure that the standard liquid has a valid period of up to 5 years in the unopened state to ensure the accuracy of calibrating.
Calibrated 240mV@25 ° C, with tamper-resistant sealing to ensure solution freshness, and manufactured in a temperature-controlled environment with Reagent grade chemicals to help quickly check ElectRode performance and determine cleaning needs.
The platinum needle element is used to achieve a wide range of measurement of +/- 1999mV, the built-in 3mol KCl gel reference solution cannot be added, and the plastic shell structure is matched with the BNC interface, which can maintain stable operation in complex environments.
With ORP Measurement range -999mV~ 999mV and temperature measurement 0~ 60 ℃, 32-bit processor for high Stability and low power consumption, IP65 Protection Rating ensures durability, automatic recognition of standard solution and five-minute automatic shutdown function to improve convenience.
Simultaneous measurement of pH, mV and temperature, pH resolution of 0.01, automatic identification of three standard buffers, input Impedance ≥ 1 × 10 ^ 12 Ω, High Stability.
Measurement accuracy +/- 2mV with relative and absolute mV measurement function, Automatic endpoint locking retains stable Measured value, fully waterproof design can be used in harsh environments, built-in system menu supports custom data locking and timed shutdown.
32-Bit high-performance processor to ensure stable measurement, ORP Measurement accuracy of +/- 2mV, with automatic temperature compensation and IP65 Protection Rating, support pH/ORP mode free switching.
With 2 point button calibrating and automatic temperature compensation function, Measurement accuracy is 0.01pH, Support Data storage 50 groups and automatically mark the time and date, Built-in USB interface for easy data transmission.