With 58mm large integrating sphere and combined LED Illuminant, it receives a wider range of reflected light, with repeability accuracy within 0.04, with 3.5-inch Touchscreen and ergonomic design.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the light transmitter and haze measurement accuracy are 0.01%, support U disk storage and USB communication, equipped with thin film magnetic fixture and liquid sample Cup.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.
Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.
Using 150mm integrating sphere and 25mm test hole, Measurement accuracy Delta R457 ≤ 0.5, support Opacity, transparency and inks absorption value and other Multi-ParaMeter detection, suitable for a variety of sample thicknesses.
Using 58mm large integrating ball and D/8 lighting mode, the repeability accuracy is within 0.04, equipped with 3.5 inch Touchscreen and ergonomic design, stable measurement and easy operation.
Measurement principle of diffuse transmission, optical density Measurement range of 6.000 OD, accuracy +/- 0.02 OD, equipped with fixed seat and bracket, support two Measurement mode, suitable for translucent material testing.
Measurement accuracy is increased by 96% with integrating sphere structure coating. Standard Deviation Delta E * ab ≤ 0.06 ensures Data Stability and supports a variety of chroma space and Illuminant selection.
The integrating sphere principle is used to achieve full luminous flux reception, the maximum measurement thickness is 55mm, and the open measurement area is equipped to adapt to any size sample. Standard light sources and compensation methods are supported to ensure data accuracy.
Using German High Sensitivity Sensor and Illuminant, with more than 96% high diffuse coating integrating sphere structure, Repeatability Standard Deviation Delta E * ab ≤ 0.06, can measure arc surface, powder and other special-shaped surfaces.
Adopt 45/0 geometrical optics structure, repeability accuracy Delta E * ab within 0.04, equipped with large integrating sphere and 3.5 inch Touchscreen, support Light spectrum reflectance Linear dispersion display and color scheme function.
Using D/8 ° illumination and integrating sphere design, the repeability accuracy Delta E * ab within 0.04, Inter-Agreement Delta E * ab 0.2, supports a variety of color difference formulas and Illuminant modes, and the measurement time is only 1.5 seconds.
Adopt 45/0 geometrical optics structure, repeability accuracy Delta E * ab 0.04, Inter-instrument Agreement Delta E * ab 0.2, equipped with large integrating sphere and 3.5 inch Touchscreen, support Light spectrum reflectance Linear dispersion display and color scheme function.
Repeatability less than or equal to 0.05, display accuracy 0.01, non-contact automatic whiteboard calibration and integrating ball dual optical path design, Type-C interface can be continuously tested 12,000 times when fully charged.
Repeatability Delta E * ab within 0.1, Measurement time of about 1.0 seconds; Non-contact automatic whiteboard calibration to avoid dirt, integrating ball double light path design to ensure stability, lightweight and portable can be continuously tested 12,000 times.