Graphite Preparer

A graphite preparator converts carbon-containing materials into a graphite structure through high-temperature heating. It is used in laboratories to prepare graphite samples for material research and coating development.
Selection
When selecting, focus on the heating temperature range, temperature control accuracy, and sample capacity. Consider the equipment material's resistance to high temperatures and ensure compatibility with commonly used sample sizes. Check the heating rate and energy consumption parameters in conjunction with the laboratory's power configuration.

Terms

Instruments

Using high purity graphite material and fuzzy PID temperature control technology, temperature control accuracy +/- 0.1 ℃, with over-temperature alarm, temperature self-setting and thermostatic timing function, panel size 400 * 300mm.

$ 808.00

Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment, support microwave digestion pretreatment and acid rush.

Using high purity graphite PFA coating heating method, Temperature range RT +~ 400 ℃, monitoring accuracy +/- 0.5 ℃, digestion number of 20 holes, suitable for a variety of sample pretreatment, atomic absorption and other analytical instruments.

Graphite electRode to reduce Polarization effect, automatic temperature compensation to ensure accuracy, Measurement range EC 0-3999μS/cm, TDS 0-2000ppm, resolution up to 1μS/cm, suitable for harsh environments.

$ 306.00

Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment needs.

Temperature control accuracy of +/- 0.1 ℃, using fuzzy PID control technology, with over-temperature alarm and temperature self-tuning function, heating material is high purity graphite, panel size 600 * 400mm.

$ 1332.00

It can process 20 samples at the same time, the temperature control accuracy is +/- 1 ℃, and the corrosion resistance design and special oxidation resistance graphite block are used to ensure that the samples are heated evenly and have a long service life.

$ 1927.00

Temperature control accuracy +/- 0.1 ℃, Temperature range RT +~ 450 ℃, using fuzzy PID control to achieve fast stability and small overshoot, with over-temperature alarm and self-tuning function, heating material is high purity graphite.

$ 912.00

PID microchip control to achieve +/- 0.5 ℃ temperature control accuracy, surrounded by heating to ensure that the temperature difference between holes ≤ +/- 1 ℃, high purity graphite heating material acid and alkali corrosion resistance, double-decked insulation design to improve safety and efficiency.

$ 1558.00

Using high purity graphite + PFA coating heating method, temperature control accuracy +/- 0.5 ℃, digestion number of 25 holes, suitable for microwave digestion pretreatment and acid treatment, supporting a variety of analytical instruments.

Using fuzzy PID temperature control technology, the temperature overshoot is small and the Stabilization time is fast; the temperature control accuracy reaches +/- 0.1 ℃, the panel size is 600 * 400mm; with over-temperature alarm and self-tuning function, to ensure the safety and accuracy of the experiment.

$ 1227.00

Temperature range RT + to 400 ℃, monitoring accuracy +/- 0.5 ℃, fast digestion and energy saving, suitable for a variety of sample pretreatment needs.

Using PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure the same batch of sample digestion effect, simple and efficient operation.

$ 2849.00

The instrument adopts PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure consistent digestion of the same batch of samples, equipped with abnormal alarm and double-decked insulation system.

$ 1219.00

Adopt PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃ @100 ℃, surround heating to ensure the same digestion effect, double-decked thermal insulation design is safe and efficient.

$ 2365.00

Articles

Wet film applicator for applying color paint to a specified wet film thickness.
A wet film applicator is a laboratory tool used to apply a predetermined thickness of wet paint film onto a flat substrate, providing the foundation for subsequent dry film performance testing.
Alignment Accuracy Control Method for Four-Sided Preparator When Used with Automatic Coating Machine
This article explores the alignment accuracy control when using a four-sided preparator in conjunction with an automatic coating machine. Alignment accuracy directly affects the uniformity of the coating and the reliability of detection.
Film applicator standardized preparation of test samples.
The film applicator is a crucial tool in fields such as coatings and inks for preparing test samples, ensuring uniform thickness and a smooth surface through standardized operations. The article introduces its scraping-based working principle and the selection between manual and automatic types.
Coating film preparation techniques: comparison between wire-wound applicators and wet film preparators
This article compares two commonly used tools in laboratory coating film preparation: the wire rod coater and the wet film applicator.
The importance of maintaining a constant speed when using a wet film applicator for coating.
When using a wet film applicator, maintaining a constant speed during the scraping process is crucial for coating uniformity. The scraping speed directly affects the wet film thickness, and fluctuations in speed can lead to defects such as streaks and uneven thickness, compromising the repeatability and accuracy of experimental results.
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.