Solid-State Moisture Gauge

Solid moisture meters detect the moisture content in materials through methods such as resistance, capacitance, or infrared. They are used to monitor the dryness of solid materials and control production processes in industries such as grain, wood, and building materials.
Selection
When selecting, consider matching the material characteristics with the detection principle: capacitive for powders and resistive for granules. Choose the measurement range based on the moisture content. Use portable types for on-site applications and online types for production lines. Pay attention to temperature effects and calibration methods.

Terms

Standards

Instruments

It can evaporate water in solid samples of 10g or less, use disposable sample bottle sampling, vaporize by heating and transport water in high purity Developing solvent, suitable for a variety of solid or quasi-solid sample analysis.

$ 3462.00

Suitable for solid-state semi-solid piercing measurement, using high-performance ceramic core liquid junction and long-life reference structure, Measurement range 0-14pH, Temperature range 0-60 ℃.

$ 251.00

Using solid state Sensor and skirt cone geometry, detection range 0.01-1120 0mg/L Cd2 +, operating range 2-12.5 pH and 0-80 ℃, stable measurement is achieved by compressing cadmium sulfide/silver sulfide sensing film.

$ 1948.00

The composite ElectRode design does not require reference ElectRode, the Solid State Sensor can be directly immersed in liquid measurement, the measurement range is 0.04 to 39000ppm, and the epoxy resin shell is durable.

$ 396.00

Temperature range RT +~ 180 ℃, the fastest few minutes to complete the measurement. With automatic alarm and Draft Shield design, support moisture and Solid content conversion at the same time, Test accuracy of 0.1%.

$ 420.00

Measurement range 0~ 80%, resolution 0.1%, support a variety of material code selection, provide LED status indication and automatic shutdown function, easy to accurately determine the moisture state.

$ 280.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using thermogravimetry principle, moisture readability of 0.01%, equipped with 500W high efficiency halogen lamp and PT100 temperature sensor, heating Temperature range 40-180 ℃, support automatic shutdown and real-time Linear dispersion display.

$ 378.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Contact angle measuring instrument measures the surface energy of resin after curing.
The contact angle measuring instrument evaluates surface energy by analyzing the contact angle formed by a droplet on a solid surface, based on the principle of Young's equation. Measuring the surface energy of resin after curing is significant for properties such as coating adhesion and bonding.
Contact Angle Meter Evaluates Wettability of Hydrophobic Coatings
A contact angle measuring instrument evaluates the wettability of hydrophobic coatings by analyzing the angle formed by a liquid droplet on a solid surface. Its principle is based on Young's equation, where a contact angle greater than 90° indicates hydrophobicity.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
How to Choose the Right Contact Angle Measuring Instrument Based on Sample Characteristics
Contact angle measurement is a key method for evaluating the wettability of solid surfaces and is widely used in fields such as materials science, coating industry, textile testing, electronic packaging, and environmental monitoring.
Porosity Control in the Preparation of Porous Coatings During the Blade Coating Process
Doctor blade coating is a wet coating technique widely used for preparing functional coatings, which involves uniformly applying a slurry containing solid particles (such as ceramics, polymers, or metal oxides) onto a substrate, followed by drying and heat treatment to form the coating.
Contact Angle Meter Selection Guide: How Can Laboratory Beginners Avoid Pitfalls?
The contact angle measuring instrument is used to analyze the wettability of solid surfaces and has applications in various fields such as materials and coatings. When selecting a model as a beginner, it is necessary to first understand key parameters such as static and dynamic contact angles and surface free energy, and then choose the configuration based on the specific application scenario.
Surface Tensiometer vs. Contact Angle Goniometer: Which One to Choose for Wetting Studies?
Surface tension meters primarily measure the surface tension of liquids and are suitable for analyzing the properties of liquids themselves, such as purity or the effects of additives. Contact angle meters, on the other hand, evaluate the wettability of solids by analyzing the contour of liquid droplets on solid surfaces, and are commonly used in surface treatment or coating research.