Wine Turbidity Meter

A wine turbidimeter measures the turbidity of wine by detecting the degree of light scattering caused by suspended particles as a beam of light passes through the wine sample. It is used to monitor the clarity and stability of beverages such as beer and wine, ensuring consistent product appearance.
Selection
When selecting a wine turbidity meter, consider matching the measurement range to the sample's turbidity, ensuring the accuracy meets process requirements, ease of operation, instrument stability, maintenance costs, and compatibility with sample types such as beer or juice.

Terms

Instruments

Optical inspection system to ensure long-term Stability, Stray Light and Color Interference to a low level, Measurement range 0-1200NTU, accuracy +/- 2% + 0.05NTU, support Manual calibration and GLP management functions.

$ 2074.00

Measurement range 0~ 100EBC, resolution 0.01EBC, equipped with low drift High Accuracy optical path system and unique positioning structure to ensure measurement accuracy and Repeatability, effective long life Illuminant to ensure long-term stable work.

$ 590.00

Measurement principle of 90 ° scattered light, Measurement range 0~ 50EBC, resolution 0.01EBC, with unique positioning structure and High Accuracy optical path system, to ensure measurement accuracy and Repeatability, low drift design to ensure long-term stable work.

$ 506.00

With automatic temperature compensation function, large TFT backlight color screen display, IP65 Protection Rating, measurement of whiteness 0~ 35% and convertible wine accuracy 0~ 22%.

$ 304.00

Using EPA custom Illuminant and chroma compensation technology, Measurement range 0.00-4000 NTU, minimum detection limit < 0.02NTU, support automatic range conversion and multiple calibrate modes to ensure the accuracy of low turbidity measurement.

$ 3527.00

With 0~ 60% w/w wine accuracy Measurement range, accuracy +/- 0.3, support automatic temperature compensation and IP65 Protection Rating, anti-light interference design.

$ 304.00

With automatic temperature compensation function, Measurement range covers 0~ 35% Brix and 0~ 22% convertible wine accuracy, accuracy of +/- 0.2, large TFT color screen display, IP65 waterproof and dustproof.

$ 304.00

Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.

$ 3878.00

With 0~ 60% v/v wine accuracy Measurement range, accuracy +/- 0.3, support automatic temperature compensation and user-defined zero point, anti-light interference design, adapt to different environment needs.

$ 304.00

Built-in Wine pH ElectRode with CPS technology, Measurement range 0.00~ 12.00pH, accuracy +/- 0.05pH@25 ° C. Compact design weighs only 46g, CR2032 battery provides 1000 hours of battery life, suitable for rapid on-site inspection.

$ 299.00

Measurement range of 0~ 35% Brix sugar content and 0~ 22% wine accuracy conversion ability, IP65 Protection Rating design, support automatic temperature compensation and user-defined zero mode, excellent anti-light interference performance.

$ 304.00

With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.

$ 2505.00

Measurement principle of 90 ° scattered light, Measurement range 0~ 400NTU, resolution 0.01, High Accuracy Optical Path System and Stable Circuit, Support Multi-turbidity Unit switch, with print interface to ensure long-term reliable work.

$ 453.00

The principle of scattered light is used for measurement turbidity, the measurement range is 0-200NTU, the resolution is 0.01NTU, the linearity is good and the operation is convenient, and it is suitable for a variety of water quality testing scenarios.

$ 262.00

Maxwell turbidity unit measurement of bacterial concentration, resolution 0.001 MCF, range 0-6MCF, with High Accuracy optical path system and low drift circuit, can store 20 records to ensure measurement accuracy and Repeatability.

$ 519.00

Articles