Using 16-bit AD converter and K-type Thermocouple, sampling speed 16 times per second, Measurement range -50 ° C to 1300 ° C, support Fahrenheit switching and data retention functions.
Four-channel configuration with K-type Thermocouple, the sampling rate can be adjusted from 1 second to 1 minute, and the thermal insulation performance can last for 60 minutes in a 500 ° C environment to achieve full temperature tracking monitoring.
Four-channel K-type Thermocouple with 0.5% accuracy, the insulation box can work continuously for 1 hour in a 300 degree environment, supports multi-rate sampling and 16000 Data storage, Stability is high and easy to operate.
Single-channel design, supports J, K, T, E, R, S, B, N-type Thermocouple Probe, internal thermistor cold junction compensation, temperature error +/- 0.21 ° C, recording interval can be flexibly set from 1 second to 18 hours.
It can simultaneously measure the temperature of 8 channels, support K-type Thermocouple temperature measurement range -200~ 1300 ℃, use true color TFT-LCD display, with data recording and upper and lower limit alarm functions, Sampling rate 1.5 seconds.
With a wide temperature measurement range from -200 ° C to 1371 ° C, accuracy up to +/- 0.5 ° C, support Manual calibration and RS232 Interface, waterproof design to ensure stable operation in humid environments.
The clamping design ensures good contact with the workpiece surface, the lightweight shape avoids affecting the temperature, the Teflon sheath is flexible and durable, with a maximum temperature resistance of 300 ° C, and the ceramic insulation guarantees accurate readings.
8-Channel synchronous collection of temperature data, support a variety of Thermocouple types, temperature range -200~ 1800 ℃, with breaking detection and upper and lower limit alarm functions, Response speed and stable data.
Waterproof design ensures safe use in humid environment, supports three Thermocouple Probe types, Measurement accuracy up to +/- 0.5 ℃, dual measurement interface can connect two Probes at the same time, equipped with data locking and temperature Unit switching function.
Four-channel K-type Thermocouple configuration, accuracy of 0.5%, insulation performance maintained at 400 ℃ for 60 minutes, support multi-rate sampling and data synchronization analysis, to ensure stable and reliable temperature mapping.
Four-channel synchronous acquisition, supports a variety of Thermocouple types, the temperature measurement range covers -200 to 1800 ° C, with broken couple detection function and upper and lower limit alarm settings, Fast Response and stable data.
With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.
Equipped with 6 measurement channels and K-type Thermocouple, supports a wide temperature range of 0-1200 ° C, uses 3.5-inch full-color Touchscreen operation, built-in rechargeable battery can work continuously for 4 hours, storage capacity up to 250,000 measurement points.
With 4-channel K-type Thermocouple, Measurement range -100 to 1300 ℃, accuracy +/- 0.3 ℃. Support continuous test 16 times, automatic charging when data is downloaded, and data is not lost after power failure, easy and intuitive operation.
Dual Probe design can measure two samples at the same time, equipped with BEPS low power error prevention system to avoid wrong readings, Measurement accuracy of +/- 0.5 ℃, support K/J/T type multiple temperature sensors, waterproof design to adapt to complex environments.