Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using platinum ElectRode high temperature corrosion resistance, drop height 30-40mm adjustable, time interval 30 +/- 1 seconds, automatically cut off the unqualified current.
Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using rectangular platinum plating ElectRode, drop time interval of 30 +/- 1 seconds, with automatic cut-off protection function.
Using 40KHz Frequency and 640KHz crystal time base circuit, the weight is only 50 grams and easy to carry, which can accurately detect air leakage sources in various environments.
Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.
Using rectangular platinum ElectRode, the ElectRode force is 1.0N +/- 0.05N, the test voltage is adjustable from 100 to 600V, and the voltage drop does not exceed 10% when the short-circuit current is 1.0 +/- 0.1A. The dripping device can accurately control the dripping volume and time interval.
Support 0 °, 10 °, 30 ° multi-angle test, equipped with 250mL liquid discharge funnel and 500mL measuringflask, can meet the needs of sanitary napkins and diapers at the same time, such as slippery penetration, re-penetration and other penetration performance measurement.
Touchscreen control, automatic constant pressure gas to ensure that the experiment in the preset vacuum, Vacuum Level range of 0~ -90KPa, a key operation automatically end the test, stable and durable performance.
Semiconductor Sensor to detect halogen gas leaks of less than 0.5 oz/year, Response Time ≤ 1 second, Sensitivity adjustable, Portable design weighing 250g, up to 9 hours of operation.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.
Using platinum sheet material, Conductivity Detector cell constant is 1, Measurement range covers 2.0~ 200 µS/cm, suitable for conventional water detection, interface is three-core socket, no temperature compensation function.
Conductivity Detector 1 with platinum sheet material. Measurement range from 200 µS/cm to 200 mS/cm. Suitable for environmental and conventional water detection without temperature compensation.
Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Measurement range of 0-200mS/cm, suitable for high Conductivity Detector liquids, equipped with 5 Meters low noise Shielding cable.
Using Platinum Sensor to ensure linear and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 20mS/cm, suitable for conventional liquid detection, Operating temperature 0~ 80 ℃.