Intelligent Viscosity Tester

The intelligent viscometer measures fluid resistance through rotating or vibrating sensors and directly displays viscosity values. It is used for monitoring the viscosity of fluids such as paints and inks, ensuring stable material flow performance during production.
Selection
When selecting, consider that the measurement range matches the sample viscosity, the temperature control accuracy meets the material characteristics, and the sensor material is corrosion-resistant. The operation interface should be simple, and the data export function should be compatible with existing recording methods.

Terms

Standards

Instruments

Using PID intelligent temperature control technology, Precision temperature control up to +/- 0.1 ℃, equipped with 7-inch Touchscreen and four-hole test position, automatically calculate viscosity and store 50 sets of data, easy and efficient operation.

$ 5399.00

Measurement accuracy of +/- 5% F.S., support intelligent speed regulation and wide voltage adaptation, can determine the absolute viscosity of Newtonian liquid.

$ 761.00

With 1~ 100000mPa · s wide range and +/- 5% F. S accuracy, it supports intelligent speed regulation and a variety of rotor configurations. Frequency changes in mains power do not affect measurement Stability.

$ 704.00

Equipped with 7-inch Touchscreen, easy to operate, viscosity range 1~ 6 million mPa · s, support rheological characteristic measurement and continuous viscosity display, with temperature sensor and gigabit network port transmission function.

$ 3375.00

500Ml capacity S6 viscosity standard oil, 20 ℃ viscosity 8.911mPa · s, 25 ℃ viscosity 7.498mPa · s, traceable to national standards, compatible with a variety of test equipment calibrating requirements.

$ 472.00

Silicone oil standard liquid viscosity value 11000cp, capacity 400ml, specially designed for Viscometer calibrated, providing stable and reliable viscosity reference standards.

$ 204.00

Using 6mm filter diaMeter, viscosity measurement range 188-684cSt, flow time 30-100 seconds, in line with international standards design, suitable for rapid viscosity evaluation of newtonian fluids, aluminum alloy structure to ensure durability.

$ 432.00

Equipped with 7 inch Touchscreen and Gigabit network port communication, measurement accuracy of +/- 1% F.S., support stepless speed measurement and multiple viscosity unit interchange, built-in RTD temperature Probe to ensure data accuracy.

$ 4088.00

With intelligent speed regulation and 8 kinds of Rotation speed selection, viscosity range 1~ 100000mPa · s, Measurement accuracy +/- 2% F. S, wide voltage adaptation 110~ 240V, can measure the absolute viscosity of Newtonian liquid.

$ 1033.00

Equipped with 7-inch Touchscreen and rheological Linear dispersion display function, support 0.1-200 rpm stepless speed regulation and +/- 1% Measurement accuracy, built-in temperature sensor for automatic viscosity conversion and fast data transmission.

$ 4088.00

Made of stainless steel, the flow hole diaMeter is 2mm, according to DIN 53211, providing accurate viscosity measurement for Newtonian or near newtonian fluids.

$ 581.00

Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.

$ 185.00

Measurement range of 25~ 120cSt, outflow aperture of 2.53mm, suitable for laboratory viscosity testing.

$ 167.00

Aperture 4.12mm, viscosity measurement range of 70~ 370cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Laboratory blade coating machine is used for analyzing the film-forming characteristics of high-viscosity slurries.
This article analyzes the characteristics of a laboratory doctor blade coater for forming films from high-viscosity slurries. It focuses on the impact of slurry rheological properties on film formation quality.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Rotation rheometer evaluates the atomization performance of water-based paint spraying.
This article introduces how to evaluate the atomization effect of water-based paint spraying using a rotational rheometer. It first explains the two stages of atomization, as well as the importance of rheological parameters such as shear viscosity, storage modulus, loss modulus, and complex viscosity.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.