Electronic Thermo-HygroMeter

The electronic temperature and humidity gauge detects environmental temperature and humidity through sensors, converting physical quantities into electrical signals for display. It is used to monitor temperature and humidity changes in laboratories, warehouses, and other locations to ensure stable storage conditions for materials.
Selection
When selecting, consider that the measurement range covers the usage scenarios, the accuracy meets the requirements, sensor types such as capacitive sensors offer fast response, calibration functions ensure data reliability, the protection rating suits the environment, and the power supply method facilitates convenient operation.

Terms

Standards

Instruments

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Using electromagnetic force equilibrated Electronic Balance and halogen radiation technology, moisture readability of 0.02%, Heating Temperature range RT + to 200 ℃, quickly complete the test in a few minutes, durable and functional.

$ 746.00

The equipment can perform continuous rotary drop test, drop height up to 1000mm, Test speed 5-20 times/min, suitable for Reliability verification of small electronic pRoducts.

$ 1053.00

Measurement accuracy up to +/- 0.2 ° C, built-in electronic flowMeter to monitor gas flow in real time to ensure stable and reliable measurement performance.

$ 2463.00

Using standard cutter to cut the specimen, equipped with a variety of abrasive wheels optional, support 250g-1000g load adjustment, test plate Rotation speed 60-70 rpm, electronic counter automatic shutdown to ensure Test accuracy.

$ 1122.00

DC motor to ensure that the operation of more than 10,000 hours, no noise vibration; Electronic temperature control accuracy High Response Fast, heating power 150W, Temperature range RT +~ 100 ℃.

$ 123.00

Adopt electronic voltage regulation circuit without electric shock, Temperature range environment temperature to 380 ℃, can work continuously, large heating area and no open flame design, avoid bumping Glass ware.

$ 123.00

Equipped with an electronic display 6-bit counter to realize automatic shutdown, the test disc Rotation speed is adjustable from 0-70, and supports multiple types of abrasive wheels and loads of 250g to 1000g to meet the testing requirements of different material standards.

$ 1606.00

Set grinding, dispersion, stirring functions in one, using electronic speed line, digital display Rotation speed, Motor Power 400W, Lift Travel 200mm, suitable for a variety of experimental needs.

$ 670.00

With bidirectional timing stirring function, Max. stirring Capacity 3L, speed range 0~ 2600rpm, electronic temperature control to ensure stable operation, suitable for small volume sample precision processing.

$ 190.00

Adopting quadrilateral pyramid mesh structure, surface chrome plating treatment enhances Abrasion Resistance and anti-corrosion performance, print width 70mm, through electronic engraving technology to ensure the accuracy of the mesh, long service life.

$ 167.00

Using electronic constant force stepless speed regulation, Speed range 0~ 8000rpm, equipped with jacket cylinder can be chilled down water, adapt to different material viscosity, directly calculate the relationship between linear velocity and reaction rate.

$ 498.00

DC motor to ensure noise-free vibration-free operation, electronic temperature control accuracy High Response, support 0-9999 minutes timing and 0-2000rpm speed regulation, heating power 400W to meet a variety of experimental needs.

$ 160.00

Adopt electronic constant force speed control circuit, digital direct display shaft Rotation speed, speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, set of dispersion function and stirring function as one, adapt to different test needs.

$ 414.00

Six synchronous Stir design can process multiple samples at the same time, using electronic temperature control technology implementation RT +~ 100 ℃ accurate temperature control, stirring speed 0~ 2000rpm to meet the needs of different viscosity liquids, DC motor to ensure smooth operation without vibration.

$ 323.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Turbidity meter selection: Basis for choosing light source type and measurement accuracy.
This article mainly introduces how to select a turbidity meter based on its light source type and measurement accuracy.
How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.