Automatic Melting Point Detector

The automatic melting point detector heats the sample through programmed temperature control, uses a photoelectric sensor to capture changes in light transmittance during crystal melting, and automatically records phase transition temperatures. It is used for purity testing and process control of plastics and chemical raw materials.
Selection
When selecting, consider matching the sample form with the sample chamber specifications, ensure temperature control accuracy aligns with material properties, the observation system must clearly display phase transition processes, the operation interface should be simple and user-friendly, and pay attention to equipment protection and routine maintenance requirements.

Terms

Standards

Instruments

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.

$ 2397.00

It can process 4 samples at a time, realize one-button measurement function, Temperature range RT +~ 400 ℃, heating rate 0.1~ 20 ℃ stepless adjustable, automatic recording of melting distance, initial melting and final melting, with 10 sets of spectrum storage and 400 Data storage capacity.

$ 3172.00

Using high-resolution video technology instead of traditional Microscope, it can process 4 samples at a time, Temperature range RT +~ 350 ℃, accuracy +/- 0.1 ℃, support powder and bulk sample measurement, automatic recording of melting range data.

$ 4414.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 320 ℃, resolution 0.1 ℃, automatically display the initial and final melting and record the melting Linear dispersion, improve measurement accuracy and reliability.

$ 1526.00

Equipped with a high definition camera module can clearly observe the sample melting process, process 4 samples at a time, Temperature range RT +~ 420 ℃, heating rate 0.1~ 20 ℃ infinitely adjustable, automatic recording of melting distance and initial melting and final melting.

$ 5754.00

Using photoelectric automatic detection technology, the temperature resolution reaches 0.1 ℃, the temperature control system applies PID regulation and PWM technology to improve the measurement accuracy and reliability, and supports automatic recording of initial melting and final melting results.

$ 1855.00

With photoelectric detection and automatic measurement function, Temperature range RT +~ 320 ℃, resolution 0.01 ℃, eight linear heating rate optional, support melting Linear dispersion recording and average calculation.

$ 1501.00

Using photoelectric detection technology to automatically identify the initial and final melting points, equipped with Platinum Resistance Sensor to ensure +/- 0.5 ℃ accuracy, support eight linear heating rate and automatic storage function, no manual monitoring can complete the measurement.

$ 1116.00

Using photoelectric automatic detection and PID adjustment technology, the temperature resolution reaches 0.1 ℃, Indication Error +/- 0.4 ℃, automatically displays the initial melting and final melting and records Linear dispersion, supports multi-speed heating rate and RS232/USB interface.

$ 1493.00

Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.

$ 654.00

High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.

$ 2607.00

Using photoelectric detection technology automatic measurement melting point, accuracy of +/- 0.2 ℃, support eight linear heating rate and platinum resistance Sensor, without manual monitoring can work stably.

$ 1190.00

With five linear heating rate setting, Temperature range RT + to 400 ℃, resolution 0.1 ℃, support capillary method and coverslip method measurement, high magnification microscopic observation of melting details, suitable for a variety of Sample types.

$ 988.00

Using 30fps high-resolution video and 720P camera to observe the sample melting process in real time, support 0.1-20 ℃/min heating rate adjustable and four capillary tubing simultaneous processing, in line with pharmacopoeia specifications.

$ 4269.00

Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.

$ 624.00

Articles

Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium Battery Separators
This article introduces the application of automatic coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional
Application of Automatic Film Coating Machines in the Preparation of Uniform Coatings in Laboratories
This article introduces the application of automatic film applicators in preparing uniform coatings in laboratories. Traditional manual coating methods are influenced by the operator's experience, making it difficult to ensure coating consistency.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Key operational points for determining the acid value of oils and fats using potentiometric titration.
This article introduces the key operational points for determining the acid value of oils and fats using potentiometric titration. The method principle involves dissolving the oil or fat sample, titrating it with a standard alkaline solution, automatically determining the endpoint based on the potential jump, and then calculating the acid value using the formula.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Key Points for Wet Film Thickness Control in the Preparation of Fluorocarbon Coatings for Photovoltaic Backsheets Using Automatic Film Coating Machines
This article introduces the key points of controlling wet film thickness in the preparation of fluorocarbon coatings for photovoltaic backsheets using an automatic coating machine. Wet film thickness directly affects the performance and uniformity of the coating after curing, making its control crucial.
Alignment Accuracy Control Method for Four-Sided Preparator When Used with Automatic Coating Machine
This article explores the alignment accuracy control when using a four-sided preparator in conjunction with an automatic coating machine. Alignment accuracy directly affects the uniformity of the coating and the reliability of detection.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Programmable Automatic Film Coating Machine: Application Techniques of Multi-Speed Function in Gradient Coating Preparation
This article introduces how the multi-segment variable speed function of a programmable automatic film applicator can be used to prepare gradient coatings.
Differential Scanning Calorimetry for Determining the Melting Point and Glass Transition Temperature of Hot Melt Adhesives
This article introduces the method of determining the melting point and glass transition temperature of hot-melt adhesives using a differential scanning calorimeter. Differential scanning calorimetry analyzes the thermal transition characteristics of materials by measuring the energy difference between the sample and a reference material.