Low-temperature thermostatic Bath circulator

The low-temperature thermostatic bath circulator reduces the temperature of the liquid medium through a refrigeration system, and uses a circulating pump to keep the medium flowing in a closed system, maintaining the set low-temperature environment. It is used in scenarios such as laboratory sample cooling, reactor temperature control, and material testing to ensure temperature stability.
Selection
When selecting, consider that the temperature range covers the experimental needs, the temperature control accuracy matches the sample requirements, the tank capacity fits the container size, the circulation flow rate meets heat exchange efficiency, the medium type is compatible with the experimental materials, and verify safety protection functions such as overtemperature alarms.

Terms

Standards

Instruments

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

It adopts transparent carbonic acid ester Bath design, with a volume of 6L, equipped with pressure/suction pump and Pt100 temperature sensor, with low liquid level protection and hardware over-temperature protection functions, and supports external circulation temperature control.

$ 1519.00

Using transparent carbonic acid ester Bath design, the highest Operating temperature of 100 ℃, equipped with 20L volume Tank body; with low liquid level protection and hardware over-temperature protection function, in line with DIN12876 standard III Safety level, support external circulation and precise temperature control.

$ 1858.00

Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, using proportional refrigeration technology and PID control, support internal and external circulation and programmed operation, with low liquid level and over temperature protection, suitable for a variety of application environments.

$ 2287.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Using transparent carbonic acid ester Bath design, the highest Operating temperature is 100 ℃, equipped with 13L volume Tank body. With low liquid level protection and hardware over-temperature protection function, support Pt100 temperature sensor calibrated, pump Flow rate up to 12L/min, provide multi-stage program control and a variety of safe operation modes.

$ 751.00

Using transparent carbonic acid ester Bath design, the highest Operating temperature is 100 ℃, equipped with pressure/suction pump to provide 22L/min Flow rate, support external circulation and Pt100 temperature sensor precise temperature control.

$ 841.00

Using transparent carbonic acid ester Bath design, the highest Operating temperature of 100 ℃, equipped with pressure suction pump to provide 12L/min Flow rate, support multi-stage program control and external temperature sensor precise temperature control, with liquid level and hardware overtemperature double protection function.

$ 1632.00

Operating temperature up to 200 ℃, equipped with 44L large capacity Bath; with low level protection and hardware over-temperature protection function, support Pt100 temperature sensor and multi-stage program control, pump Flow rate up to 22L/min.

$ 1429.00

Temperature range -20 ℃ to 150 ℃, equipped with pressure/suction pump and Pt100 Sensor, supports multi-stage program control and external temperature sensor, with hardware over-temperature protection and multiple safety modes.

$ 977.00

Temperature range -20 ℃ to 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1K, equipped with pressure/suction pump and hardware over-temperature protection, supports multi-stage program control and external Sensor interface.

$ 909.00

Temperature range -20 ℃ to 150 ℃, Temperature Fluctuation +/- 0.05~ 0.1K, using pressure/suction pump and Pt100 Sensor, support multi-stage program control and external Communication interface.

$ 1090.00

Adopt pressure suction pump to automatically adapt to external load, maximum Flow rate 12L/min; support multi-stage program control, each section is up to 999 hours; with hardware over-temperature protection and liquid level protection functions, in line with safety standards.

$ 841.00

With heating and cooling functions, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support 10-stage program control and external communication, pump Flow rate 12L/min, suitable for internal and external circulation applications.

$ 1146.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.