Physical and Chemical Drying Oven

The physical and chemical drying oven heats air through electric heating elements and uses a fan to circulate hot air to ensure uniform temperature inside the chamber, which is used to remove moisture from samples or cure coatings. In the laboratory, it is commonly used for drying treatments of materials such as coatings and plastics, as well as for the rapid curing of paper inks and stability testing of components.
Selection
When selecting, ensure the temperature range covers experimental needs, the inner chamber material's corrosion resistance matches sample characteristics, and the chamber volume is determined by sample dimensions. Pay attention to parameters such as temperature fluctuation and uniformity, and check the integrity of the door seals. The type of fan affects heat exchange efficiency, and the temperature control accuracy should correspond to experimental requirements.

Terms

Standards

Instruments

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure Spreader uniformity and test accuracy.

$ 391.00

It can simultaneously measure more than 10 physical paraMeters such as angle of repose and tap density. The vibration frequency is 300 rpm, and the repeatability error is ≤ 3%. It supports a variety of national standard test methods to meet the needs of comprehensive characteristic analysis of powder.

$ 5528.00

Using film lamination technology, with 0.29mm paper Film thickness and surface Laminating, providing uniform film Spreader and solvent chemical resistance, easy hiding power, Opacity test.

$ 618.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

Using film lamination technology, with excellent solvent and chemical resistance, paper Film thickness 0.29mm and no fluorescent whitening agent to ensure accurate and reliable test results.

$ 635.00

Using film lamination process, with solvent resistance and chemical resistance, paper Film thickness 0.29mm, Laminating to ensure uniformity of Spreader, with annotation section for easy recording of test information.

$ 244.00

Cuboid studio improves volume utilization, drying time is reduced by more than 40%; Temperature range RT + 10~ 200 ℃, Vacuum Level 133Pa; double-decked Glass door is easy to observe, can be filled with inert gas anti-oxidation, stainless steel liner is durable and easy to clean.

$ 746.00

Inner Chamber dimensions 450 × 450 × 450mm, Vacuum Level < 133Pa, using microcomputer temperature control technology, dual-screen digital tube display, can be filled with inert gas, suitable for drying heat-sensitive substances and explosion-proof safety.

$ 2026.00

The water pRoduction rate reaches 5L/h, the water intake Flow velocity is 0.8L/min, and the RO membrane intelligent anti-scale flushing and automatic domestic circulation system are supported to ensure the stability of ultrapure water quality, which is suitable for a variety of experimental needs.

$ 1897.00

Using film lamination technology, it has excellent solvent and chemical resistance, ensuring uniform film Spreader, paper Film thickness 0.29mm, surface Laminating enhanced durability, suitable for a variety of test environments.

$ 443.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
How to Choose an Electric Hot Air Drying Oven? Read This Guide to Avoid Pitfalls
This article explains how to choose an electric air drying oven, with key performance parameters including temperature range, fluctuation, uniformity, heating rate, and working chamber size, which directly affect experimental outcomes.