Differential Thermal Melting Point Apparatus

The differential thermal melting point instrument measures the temperature difference between the sample and a reference material through programmed heating, detecting phase transition processes such as melting and crystallization of substances. It is used to determine the melting point, thermal stability, and reaction characteristics of materials, and is suitable for quality control and research in fields such as chemical engineering, pharmaceuticals, and materials science.
Selection
When selecting a differential thermal melting point apparatus, considerations should include a temperature range that covers sample requirements, the precision of heating rate control which affects resolution, and sensor sensitivity that determines the detection limit. The sample crucible material must be compatible with the test substance, and software functionality should support data export and analysis. Maintenance convenience and after-sales support should also be taken into account.

Terms

Standards

Instruments

With dual measurement function of capillary method and coverslip method, support eight linear heating rate of 0.2-5 ℃/min, Temperature range RT + to 320 ℃, resolution 0.1 ℃, can clearly observe the melting process of trace samples, suitable for dark, low purity and analysis samples.

$ 2015.00

Using imported E-even Sensor, accuracy of 0.001mw, Sensitivity, good repeability; Support multi-atmosphere automatic switching, temperature range RT-600 ℃, Glass transformation, melting point, oxidation induction period and other tests.

$ 8949.00

With 0.2~ 5 ℃/min eight linear heating rate control, Temperature resolution of 0.1 ℃, Support Capillary Method and Cover Slip Method Measurement mode, Can observe 40X~ 100X zoom sample melting process.

$ 2244.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.

$ 2397.00

Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.

$ 654.00

With 0.2-5 ℃/min eight linear heating rate, Temperature range RT + to 320 ℃, support capillary method and coverslip method two Measurement mode, can observe the details of the whole process of sample melting.

$ 3023.00

It can process 4 samples at a time, realize one-button measurement function, Temperature range RT +~ 400 ℃, heating rate 0.1~ 20 ℃ stepless adjustable, automatic recording of melting distance, initial melting and final melting, with 10 sets of spectrum storage and 400 Data storage capacity.

$ 3172.00

With five linear heating rate setting, Temperature range RT + to 400 ℃, resolution 0.1 ℃, support capillary method and coverslip method measurement, high magnification microscopic observation of melting details, suitable for a variety of Sample types.

$ 988.00

Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.

$ 624.00

Using high-resolution video technology instead of traditional Microscope, it can process 4 samples at a time, Temperature range RT +~ 350 ℃, accuracy +/- 0.1 ℃, support powder and bulk sample measurement, automatic recording of melting range data.

$ 4414.00

High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.

$ 2607.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 320 ℃, resolution 0.1 ℃, automatically display the initial and final melting and record the melting Linear dispersion, improve measurement accuracy and reliability.

$ 1526.00

Using PID temperature control technology to ensure accurate and stable temperature, temperature resolution of 0.1 ℃, support capillary method and hot table method two measurement methods, microscopic camera real-time display of melting process, data can be stored and transmitted.

$ 1521.00

Equipped with a high definition camera module can clearly observe the sample melting process, process 4 samples at a time, Temperature range RT +~ 420 ℃, heating rate 0.1~ 20 ℃ infinitely adjustable, automatic recording of melting distance and initial melting and final melting.

$ 5754.00

With five linear heating rate control, Temperature resolution of 0.1 ℃, support capillary method and coverslip method Measurement mode, high power microscopic observation is suitable for dark, low purity and analysis samples.

$ 859.00