High-temperature nitrogen-filled Oven

The high-temperature nitrogen-filled oven performs material drying or heat treatment in an oxygen-free environment by heating the cavity and filling it with nitrogen. It is used to prevent oxidation, remove solvents, cure coatings, etc., and is suitable for processing heat-sensitive materials in industries such as coatings and plastics.
Selection
When selecting, consider the temperature range and uniformity, nitrogen purity and flow control, corrosion resistance of the chamber material, safety protection devices, and energy consumption indicators, matching them with specific process requirements and material characteristics.

Terms

Standards

Instruments

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Using Dynamic Low Temperature Nitrogen Adsorption Method and High Sensitivity Sensor, the test range from 0.0005m ²/g has no upper limit, the repeatability error ≤ +/- 3%, and the single sample test is completed in about 3 minutes.

$ 7980.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Adopt automatic nitrogen measurement distillation system, nitrogen measurement range 0.1-200 mgN, collection rate ≥ 99%, repeability rate < +/- 1% relative to Standard Deviation, semi-automatic working mode, distillation time 5-15 minutes, suitable for a variety of sample analysis.

$ 493.00

Using purge and trap technology, the temperature control accuracy can reach +/- 0.5 ℃, 12 samples can be processed simultaneously, and the nitrogen consumption can be adjusted at 330ml/min/sample to achieve rapid anaerobic condensation.

$ 430.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

The cuboid studio has a large effective volume utilization rate, and the drying time is reduced by more than 40% compared with the traditional Vacuum Chamber; Temperature range RT + 10~ 200 ℃, Temperature Fluctuation +/- 0.1 ℃, to ensure accurate and reliable; can be filled with inert gas to prevent oxidation.

$ 548.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Purge and trap technology implementation of rapid oxygen-free condensing, temperature control accuracy of +/- 0.5 ℃, nitrogen consumption of 330ml/min/sample can be adjusted, support room temperature to 100 ℃ accurate temperature control.

$ 622.00

Cuboid studio improves volume utilization, drying time is reduced by more than 40%; Temperature range RT + 10~ 200 ℃, Vacuum Level 133Pa; double-decked Glass door is easy to observe, can be filled with inert gas anti-oxidation, stainless steel liner is durable and easy to clean.

$ 746.00

Purge and trap technology implementation of rapid oxygen-free condensing, temperature control accuracy of +/- 0.5 ℃, support 36 samples at the same time, nitrogen consumption can be adjusted to 330ml/min/sample, digital temperature control to ensure accurate and reliable operation.

$ 719.00

Double needle automatic switching angle to improve condensing efficiency, support 1-8 bit Sample Handling, temperature control accuracy of +/- 0.5 ℃, with independent nitrogen channel and overheating protection to ensure safe and stable operation.

$ 7496.00

Optical inspection system using imported cold Illuminant and narrow band interference, Optical inspection stability is less than 0.002A/20min, digestion temperature accuracy +/- 0.5 ℃, support COD and ammonia nitrogen dual paraMeter measurement, can save multiple standard Linear dispersion and data.

$ 1548.00

Cuboid Studio improves space utilization, double-decked Tempered Glass Door for easy observation, Silicone Rubber Door Seal ensures High Vacuum Level, Temperature range RT + 10~ 250 ℃, Temperature fluctuation +/- 1 ℃.

$ 4009.00

The cuboid studio improves the volume utilization rate, and the drying time is reduced by more than 40% compared with the traditional Vacuum Chamber; the stainless steel 316 material is used, the Vacuum Level is 133Pa, and the double-decked Glass door is easy to observe and can be filled with inert gas to prevent oxidation.

$ 1000.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.