Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.
Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.
Measurement range of 0~ 1250μm using magnetic Induction principle, with +/- 3% error accuracy and 0.1μm resolution, supports single continuous two Measurement mode, equipped with wear-resistant metal probe to ensure measurement Stability.
Adopt magnetic Induction principle to measure 0-1250μm thickness, equipped with line Probe measurement groove and narrow area, support single point and two point calibrating, with automatic matrix recognition and undervoltage prompt function.
Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.
Using the magnetic induction method, the measurement range is 0~2000 μm, with an error of ±5%, a resolution of 0.1 μm. It supports separate probes and low-voltage alerts, and is suitable for various types of coatings.
Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.
Using magnetic Induction principle, Measurement range of 0-10000 μ m, support one and two point calibrating, split structure design can adapt to a variety of Probe types, to meet different Coating thickness measurement needs.
Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.
Using magnetic principle, Coating thickness can be measured within 10 microns, Probe wear-resistant times more than 500,000 times, with single point, five point calibrate and Data storage function, suitable for inner hole or narrow position.
Using magnetic Induction principle, automatically identify magnetic metal substrate, high wear-resistant carbide Probe service life of more than 500,000 times, with zero point, single point, five point Adjustment, can store 1600 measurement data and connect to computer software.
Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.
Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 500μm, resolution of 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support USB data communication.
Using magnetic and eddy current two thickness measurement methods, Measurement range 0-1250μm, with automatic identification of iron and non-iron matrix function, support single point and two point calibrating, with power supply undervoltage indication and statistical function.
Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, resolution 0.1μm, can store 99 sets of data and support USB and Bluetooth transmission, equipped with wear-resistant hard metal probe.