Plane GlossMeter

The gloss meter projects light onto the sample surface at a fixed angle, and the detector captures the intensity of the reflected light to calculate the gloss value. It is used to measure the specular reflection capability of flat surfaces such as paper, coatings, and plastics, and is applied in quality control and product development to assess surface smoothness.
Selection
Select the appropriate measurement range based on the gloss range of the material to be tested, taking into account the measurement angle (20° for high gloss, 60° for general use, or 85° for low gloss). Ensure the instrument complies with industry standards such as ASTM D523, verify the traceability certificate of the calibration plate, and confirm that the operating environment is free from vibration and strong light interference.

Terms

Standards

Instruments

Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.

$ 428.00

With 60 ° Measurement Angles and 9 * 15mm Measuring Area, the repeatability is up to +/- 1GU, with automatic check and correction standard board function and 30-second automatic shutdown design, which meets the requirements of JJG696 secondary working Glossmeter.

$ 167.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 999GU, Measuring Area 18 * 36mm, Built-in rechargeable battery can be used continuously for more than 40 hours, Stability 1.2GU.

$ 409.00

With 2x3mm minimum measurement diaMeter, it can measure any curved surface sample; Repeatability up to 0.2GU, using dual optical path technology and high-quality Sensor; Built-in simple and statistical Measurement mode, support Glossiness comparative analysis.

$ 4559.00

Made with precision machining technology, excellent surface Smoothness, suitable for mainstream Glossmeter models, providing stable and reliable calibrated benchmarks, and stable repeability performance.

$ 119.00

Glass grinding liquid interface and silver ion capture hydrazine structure, Measurement range 1-12pH, Temperature range 0-60 ℃, suitable for object surface and droplet sample detection.

$ 251.00

Dual angle measurement 20 ° and 60 °, Stability less than +/- 0.4GU/30Min, Repeatability 0.5GU, can store 254 sets of data, portable and lightweight design, Automatic calibration without manual adjustment.

$ 323.00

Measurement range from 5mm, depth up to 22mm, suitable for a variety of Roughness Gauge to achieve profiled surface detection.

$ 275.00

Using thermal printing technology, it is designed for use with testing instruments. It can directly connect the color difference Meter and Glossmeter to achieve real-time output of measurement data and report generation.

$ 220.00

Using 20 °/60 ° double angle measurement, can automatically calculate the fog shadow value, Repeatability +/- 1.2GU, small size only 380g, super power saving design one battery can measure 100,000 set of data.

$ 759.00

Glass disc diaMeter 240mm, Rotation speed 75 +/- 5rpm, using microcomputer control to achieve reliable operation, compact structure for easy assembly and disassembly and paraMeter change.

$ 1558.00

The transient plane heat source method is used, the test time can be set for 5-160 seconds, and the test range is 0.0001-300W/(m * K). The sample is nondestructive tested, and the Probe double helix structure is combined with the exclusive mathematical model to analyze the data.

$ 6851.00

Adopt 1.5x3mm elliptical measurement port, specially designed for concave surface, Measurement accuracy +/- 1.2GU, Stability +/- 0.4GU, compact and portable, suitable for complex shape surfaces.

$ 598.00

Adopt single chip microcomputer automatic control, grinding disc diaMeter 220mm, load weight up to 2.92kg, compact structure, easy assembly and disassembly, suitable for pigment physical performance inspection.

$ 1106.00

Adopt 60 ° standard Measurement Angles, Measurement range 0~ 200GU, Repeatability +/- 1GU, equipped with 3.5-inch high-resolution color display, built-in rechargeable battery to support long-term continuous work.

$ 296.00

Articles

The coating machine applies planar optical waveguide cladding material to the surface of optical fibers.
This article introduces the technique of using a coating machine to apply planar optical waveguide cladding materials onto the surface of optical fibers. It analyzes the characteristics of the cladding materials, such as viscosity and surface tension, and their impact on coating quality.
The coefficient of friction measures the true slipperiness value of stacked paper.
This article introduces the measurement of the coefficient of friction of paper, which determines its "slipperiness." The measurement is conducted using the plane sliding method to obtain both static and kinetic friction coefficients under standard conditions.
Paper smoothness and roughness
Paper smoothness and roughness are key parameters that describe the flatness of the paper surface, and they complement each other. Smoothness refers to the extent to which the paper surface approaches an ideal plane, while roughness reflects the amplitude and frequency of surface irregularities.
Detailed Explanation of Laboratory Vacuum Adsorption Platform: Flatness is the Cornerstone of Successful Coating
The vacuum adsorption platform is a key device in coating experiments, which stabilizes the substrate by negative pressure adsorption, providing a reference plane for coating. The flatness of the platform surface is crucial, as even minor deviations can lead to defects such as uneven coating thickness or the appearance of streaks.
Application of Wire Bar Coater in the Preparation of Coating, Ink, and Printing Samples
A wire-wound rod coater is a laboratory tool used for preparing uniform wet film coatings on flat substrates, widely applied in the production of samples in the coatings, inks, and printing industries.