Temperature and Humidity Control Record

Temperature and humidity control records monitor environmental temperature and humidity data through sensors and automatically store them. Their role is to track environmental changes in real time, ensuring stable conditions for experiments or production. They are applied in laboratories, warehouses, workshops, and other locations requiring constant temperature and humidity.
Selection
When selecting, consider whether the measurement accuracy and range meet the requirements, whether the recording interval and storage capacity can cover the monitoring period, and ensure the device has calibration capabilities. Prioritize models with protection ratings suitable for the usage environment, and ensure the interface types are compatible with the existing system.

Terms

Standards

Instruments

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

Equipped with 7.0 inch Touchscreen controller, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., using French Taikang Compressor and multi-wing air supply circulation to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 6560.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.

$ 5307.00

With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.

$ 10401.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

With -40~ 150 ℃ Temperature range and 20~ 98% Humidity control, environmentally friendly refrigerant and double-decked airtight design, support multi-stage program editing and fast temperature Humidity control, easy to move and observe.

$ 8465.00

Adopt microcomputer temperature and humidity controller, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, equipped with mirror stainless steel liner and observation window, support programmable control and multiple safety protection functions.

$ 4843.00

Temperature range -40~ 150 ℃ and Humidity control 30~ 95% R. H, using programmable multi-stage control and independent temperature limit alarm system, equipped with test holes and can be pulled out of the water Tank for easy operation.

$ 9843.00

Temperature range -40~ 150 ℃, humidity control 30~ 98% R. H, Temperature Uniformity ≤ +/- 2 ℃, using PID control solid state relay and steam boiler humidification to ensure stable and reliable operation.

$ 12579.00

Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.

$ 6691.00

Adopt 7.0 inch large screen controller, temperature control accuracy +/- 0.1 ℃, humidity control accuracy +/- 1% R.H., equipped with independent temperature limit alarm system, support multi-wing air supply cycle to ensure uniform temperature.

$ 6157.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
Vicat Softening Point Tester evaluates the heat deformation resistance of resins.
The Vicat softening point tester is used to measure the thermal deformation resistance of resins. It heats and applies pressure to the specimen until it deforms by 1 millimeter, recording the temperature at that point as the softening point.
Xenon lamp aging test chamber evaluates the long-term outdoor performance of resins.
Xenon lamp aging test chambers simulate environmental conditions such as sunlight, temperature, and humidity to accelerate the testing of the weather resistance of materials like resins in a laboratory setting.
Peel strength tester measures the peel force of hot melt adhesive resin.
The peel strength tester is used to measure the adhesive properties of hot melt adhesive resins, simulating the actual peeling process by recording changes in force values through constant-speed stretching.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Adhesion Tester Pull-Off Method for Determining Adhesion Strength of Varnish
This article introduces the test method for measuring the adhesion strength of varnish using the pull-off method. It involves adhering test cylinders to the coating and substrate with adhesive, then vertically pulling them apart with an instrument to record the maximum pulling force and calculate the adhesion strength.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.