Acid-base concentration Meter

An acid-base concentration meter determines the content of acids or bases by measuring the electrical conductivity of a solution. It is used to monitor the concentration of acidic or alkaline solutions in industrial processes, commonly found in settings such as chemical engineering and wastewater treatment.
Selection
When selecting, consider that the measurement range covers process requirements, the electrode material has corrosion resistance, the temperature compensation function adapts to the on-site environment, the protection rating matches the usage conditions, and the calibration method is simple and reliable.

Terms

Standards

Instruments

The samples were treated by acid-base cooking method, and 6 samples could be measured each time. The repeatability error of the absolute value of crude fiber content below 10% did not exceed 0.4%, and the determination time was about 100 minutes.

$ 912.00

Supports multiple titration types and can store up to 100 titration methods. With a five-point pH calibrate 、 +/- 0.001 pH accuracy and a waterproof body, it can be connected to the Automatic sampler for efficient analysis.

$ 16265.00

Supports multiple titration types and Direct Measurement modes with five-point calibrated and 0.001mL resolution Burette, automated setup for Sample injectors, optimized desktop space and waterproof and durable design.

$ 9759.00

Support dynamic titration and preset endpoints and other modes, titration analysis Repeatability of 0.20%, Potential Measurement range -1800.0~ 1800.0mV, can store 200 sets of results and comply with GLP specifications.

$ 4066.00

It has 0.20% titration analysis Repeatability, supports dynamic titration and other modes, adopts PWM modulation and stirring technology implementation software speed regulation, can store 50 sets of titration results and support firmware upgrade and expansion functions.

$ 3002.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

Measurement range 0.00-2 ppm, accuracy +/- 0.04ppm, based on LED Illuminant and Color reaction principle, suitable for low concentration water quality detection.

$ 215.00

Measurement range 0.0-15 ppm, accuracy +/- 0.3ppm +/- 5% reading, using LED@525nm Illuminant, based on amino acid method for rapid detection of phosphoric acid salts, easy to operate and suitable for laboratory and field.

$ 209.00

Adapted to BNC interface pH ElectRode, supports 0.0-14 pH range calibrate, adjustable dose relay configuration is higher or lower than the user set point dosing, with timeout dosing protection function, the delay time is adjustable by 5-30 minutes.

$ 480.00

Using 525nm LED Illuminant, Measurement range 0.0-30 ppm, accuracy +/- 1.0ppm, based on amino acid method to achieve high Sensitivity phosphoric acid salt detection, suitable for a variety of water quality environments.

$ 215.00

Using 525nm LED Illuminant to ensure Stability, Measurement range 0-200ppb, accuracy +/- 5ppb, support ascorbic acid detection, with Automatic calibration verification function.

$ 215.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F.S, Response Time ≤ 30S, support a variety of signal output and remote alarm functions, with explosion-proof structure and intelligent Sensor technology.

$ 912.00

With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.

$ 106.00

Using quartz time base technology to ensure accurate measurement, Maximum Measured value 750N, Real-time display of tension data and support for voice prompts, automatic storage of upper and lower limit setting values, providing USB, RS-232 and Bluetooth Data output methods.

$ 390.00

Standard light sources including D65 and UV, seamless construction to ensure no light leakage, special steel plate base for enhanced durability, no preheating and low energy consumption, support for Illuminant use time display and automatic switching function.

$ 428.00

Articles

How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Key points for measuring the pH of water-based ink with a pH meter
This article introduces the key steps for measuring the acidity or alkalinity of water-based inks using a pH meter.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
Application of Salt Spray Test Chambers in Corrosion Resistance Testing of Automotive Components
The salt spray test chamber simulates a salty and humid environment to accelerate the testing of the corrosion resistance of automotive components. Its principle is based on electrochemical corrosion, allowing for the control of key parameters such as salt concentration and temperature.