Fluorescent Light Source Box

The fluorescent light source box is equipped with specific wavelength fluorescent lamps, which excite fluorescent substances on the sample surface to produce visible light reactions. It is used to detect the content of fluorescent whitening agents in materials such as paper and plastic, comparing the differences in fluorescence intensity between the sample and the standard sample during quality inspection.
Selection
When selecting, consider the matching degree between the lamp wavelength and the detection standard, ensure the chamber size is suitable for the samples to be tested, and the observation window should be UV-proof. Pay attention to the lamp lifespan and replacement costs, the operation interface should be user-friendly, and ensure the detection environment is light-proof.

Terms

Standards

Instruments

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Light spectrum LED light source, support sample surface free positioning measurement, repeability accuracy ≤ E * ab ≤ 0.07, Measurement speed of only 1.0 seconds, lightweight and portable.

$ 2623.00

Using LED Illuminant and 45/0 illumination conditions, Measurement range 0~ 199.9, resolution 0.1, can detect Fluorescent Whitening Agent and measure increased whiteness, Repeatability ≤ 0.3.

$ 417.00

Adopt D65 light source in line with ISO3664 international standards, color rendering index up to 98, equipped with 36W lamp and light source Timer, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1655.00

Repeatability of 0.2 for measurement of diffuse reflection factor using 457 nm blue wavelength can detect Fluorescent Whitening Agent and calculate fluorescence whiteness value, which is suitable for surface whiteness analysis of various materials.

$ 554.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

The imported cold light source does not need to be preheated for 100,000 hours, the detection limit is 0.01mg/L, and the digestion Colorimetric integrated tube is safe and fast. It can store 4000 sets of data and has a variety of transmission interfaces.

$ 816.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

It can measure the blue light diffuse reflection factor R457, analyze the fluorescent whitening agent, and print the results directly with a built-in micro-printer, repeatability error ≤ 0.1, support Opacity and light absorption coefficient measurement.

$ 1348.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illumination up to 3000LX, life more than 10,000 hours, uniform irradiation surface and no stroboscopic, flexible adjustment of light box position and angle according to test requirements.

$ 12305.00

Double light source in line with ISO3664 international standards, color rendering index up to 98, with light source Timer, all-metal structure, large folio size easy to operate, accurate proofreading Color deviation.

$ 1784.00

Utilizing a 360-780nm composite full-spectrum LED light source, equipped with a 256-pixel CMOS detector and a concave grating, it achieves spectral acquisition at 10nm intervals, supporting micro-transmittance measurements and a variety of optical index tests.

$ 6851.00

The imported cold light source does not need to be preheated for 100,000 hours, supports 0.001mg/L high Sensitivity detection, digests Colorimetric integrated tube to make the measurement safe and fast, can store 4000 sets of data and support multi-mode power supply.

$ 4721.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Key Technical Points for Determining Arsenic and Mercury in Water Using Atomic Fluorescence Spectrophotometry
This article introduces the key techniques for determining arsenic and mercury in water using an atomic fluorescence spectrometer. The experiment requires attention to safety precautions, regular maintenance of the instrument, and proper disposal of waste liquids.
Phosphor films and quantum dot coatings are uniformly applied using a coating machine.
This article introduces the significance of phosphor films and quantum dot coatings in optoelectronics and display technologies, highlighting that their performance depends on the uniformity, thickness, and density of the coatings.