Using platinum plate method measurement surface tension, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system, measurement process without vibration interference, support dynamic speed adjustment and a variety of Data analysis functions.
The ring method is adopted, the resolution reaches 0.1mN/m, supports automatic stop and average calculation, and is equipped with 24-bit AD converter and LVDT displacement Sensor to ensure Test accuracy and Repeatability.
Ring test and reference material correction, resolution 0.01mN/m, equipped with 24-bit AD converter and LVDT displacement Sensor, support automatic stop and averaging functions to ensure test Linearity and repeability accuracy.
With 4.3-inch Touchscreen operation, the electromagnetic force equilibrating Sensor ensures high Sensitivity and 0.1mN/m accuracy, supports platinum plate method and ring method dual mode, fully automatic measurement direct display results, in line with many international standards.
Using platinum plate method measurement, accuracy of 0.1mN/m, equipped with 7-inch Touchscreen and electronic level, support automatic lifting and data management, to ensure stable and reliable measurement.
Sensor using electromagnetic force equilibrating principle, Sensitivity and high accuracy, support platinum plate method and platinum ring method, automatic measurement without calculation, surface tension Measurement range 0~ 500mN/m, accuracy 0.01mN/m, real-time display Linear dispersion and preservation results.
Measurement range 0-200mN/m, accuracy +/- 0.02mN/m, support Automatic calibration and temperature compensation, real-time display test Linear dispersion and export Excel data.
Adopt automatic lifting system, the lifting speed can be adjusted from 0 to 300mm/min, equipped with electronic level to ensure Measurement accuracy, built-in measurement program to eliminate human interference, support dynamic smooth operation to reduce vibration impact.
Using platinum ring measurement, accuracy of 0.1mN/m, equipped with electronic level and automatic lifting system, eliminate vibration effects, support dynamic measurement and data management, to ensure experimental Repeatability and accuracy.
Measurement range 0-400mN/m, accuracy up to 0.1mN/m, support Automatic calibration and temperature compensation, real-time display of test Linear dispersion and export of Excel data.
Using platinum ring measurement, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system to ensure stable and reliable measurement process, support dynamic smooth operation to reduce vibration interference.
Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.
Using platinum ring measurement, accuracy of 0.001mN/m, lifting speed of 0~ 300mm/min adjustable, built-in electronic level and automatic measurement program to ensure data accuracy and Repeatability.
Using platinum plate or ring method measurement, the range is 0~ 400mN/m, the minimum resolution is 0.1mN/m, the manual lifting and lowering points are fast and micro-adjusted, and the output data of RS232C interface is supported.
Adopt electromagnetic force equilibrating Sensor, accuracy of 0.01mN/m, Measurement range 0-500mN/m, support platinum plate ring method, automatic operation without calculation, one-click zero correction, ensure high Repeatability and Data Traceability.