Desktop High-Temperature Drying Oven

The benchtop high-temperature drying oven heats the air inside the chamber through electric heating elements and uses forced convection to ensure uniform heating of samples. Moisture is expelled through exhaust vents. It is used in laboratories for processes such as material drying, heat treatment, and curing, and is suitable for sample processing in industries like coatings and plastics.
Selection
When selecting, focus on the temperature range to cover experimental needs, uniformity affecting processing effectiveness, material corrosion resistance for extended service life, temperature control accuracy related to stability, volume determined by sample size, and safety features including over-temperature protection and explosion-proof design.

Terms

Standards

Instruments

Support 0-3000um Coating thickness adjustment, travel speed 0-5m/min, Oven temperature 40-150 ℃; Modular head can switch extrusion, Drawdown blade and other Spreader functions, integrated tension closed-loop control and infrared drying options.

$ 9433.00

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Temperature range Rt + 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, Equipped with Forced Circulation Convection Channel and High Accuracy Platinum Resistance Sensor to ensure a stable high temperature environment, suitable for Sampling Handling and catalyst activation.

$ 359.00

Ceramic fiber liner and door seal, high temperature and easy to clean; equipped with P.I.D fuzzy logic controller, Temperature Fluctuation +/- 0.5 ℃, support 7 groups of 63 steps programmable operation, circulating fan Rotation speed adjustable to ensure accurate and safe experiments.

$ 1711.00

Ceramic fiber material, high temperature performance, temperature control accuracy of +/- 0.5 ℃, programmable multi-stage control, support 63 steps Program settings, easy to automate complex experiments.

$ 2378.00

Ceramic fiber material, Temperature range RT + 20~ 400 ℃, liner size 450 × 450 × 450mm, with multi-stage programmable control, independent temperature limit alarm and fast and stable temperature control function, easy to clean and automatic operation.

$ 2052.00

Temperature uniformity with natural convection design, temperature control accuracy of +/- 0.5 ° C, volume of 70L, independent temperature limit alarm system and timing function for 9999 minutes, suitable for a variety of drying sterilizing applications.

$ 761.00

The natural convection cycle design ensures uniform temperature, temperature control accuracy of +/- 0.5 ℃, timing function up to 9999 minutes, suitable for drying, sterilizing and other applications.

$ 1569.00

Temperature range up to 500 ℃ and Fluctuation only +/- 1 ℃, equipped with hot air circulation system to ensure Temperature uniformity, support independent temperature limit alarm and RS485 Communication interface to meet the precise temperature control requirements in high temperature environment.

$ 1637.00

Using ceramic fiber material, Temperature range RT + 20~ 400 ℃, liner size 980 × 1000 × 780mm, support multi-stage programmable control, independent temperature limit alarm system to ensure safe and stable operation of the experiment.

$ 5829.00

The maximum effective temperature is 600 degrees Celsius, which is better than conventional 500-degree equipment; it is equipped with an independent temperature limiter to set the upper temperature limit and double protect high-value materials; the liner is made of thickened 304 stainless steel, which is resistant to high temperature and corrosion.

$ 1064.00

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Temperature range RT + 20~ 400 ℃ and Fluctuation only +/- 1 ℃, equipped with hot air circulation system to ensure Temperature uniformity, support 1~ 9999 minutes timing function, optional independent temperature limit alarm and RS485 interface to enhance security and data recording.

$ 703.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.