Using electromagnetic force equilibrating Sensor, accuracy of 0.01mN/m, support platinum plate and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
Measurement accuracy of 0.1mN/m using electromagnetic force equilibrating Sensor, support platinum plate method and platinum ring method dual method, automatic operation without manual calculation, real-time display Linear dispersion and save data.
Sensor using electromagnetic force equilibrating principle, Sensitivity and high accuracy, support platinum plate method and platinum ring method, automatic measurement without calculation, surface tension Measurement range 0~ 500mN/m, accuracy 0.01mN/m, real-time display Linear dispersion and preservation results.
Using platinum plate method or platinum ring method for measurement, with 0-600mN/m wide Measurement range and 0.01mN/m high resolution, standard error +/- 0.02mN/m, equipped with large-screen LCD display and real-time Linear dispersion analysis software, support platform slow and fast lift switching.
Sensor using electromagnetic force equilibrating principle, accuracy of 0.1mN/m, platinum plate method and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
Using Platinum Sensor and Gel KCL Reference Solution, Operating temperature range is 0~ 60 ℃ to ensure stable reference potential and good sensing ability.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
Using Platinum ElectRode, Glass Shell Structure, Temperature range 0-50 ℃, Dimension 12 * 120mm, BNC connector to ensure stable connection.
Measuring methods of platinum plate and platinum ring are supported, with resolution up to 0.01mN/m, equipped with fast fine-tuning manual lifting platform, and can display data in real time through RS232 interface.
Using Platinum Sensor to ensure fast and stable measurement, with 1-3 point Adjustment, Measurement accuracy of 1% F.S., support automatic temperature compensation and replaceable ElectRode design.
Conductivity Detector 1 with platinum sheet material. Measurement range from 200 µS/cm to 200 mS/cm. Suitable for environmental and conventional water detection without temperature compensation.
Equipped with 200 +/- 0.2g Koenig pendulum and 500g platinum saz pendulum two configurations, the swing period is 1.4 +/- 0.02s and 1 +/- 0.001S, through the photoelectric system automatic measurement of film damping time, to meet the different standards of test requirements.
Using Platinum Sensor to ensure linear and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 20mS/cm, suitable for conventional liquid detection, Operating temperature 0~ 80 ℃.
Platinum Sensor ensures measurement Stability, built-in temperature sensor automatically senses sample temperature, ElectRode constant K = 1, Operating temperature range 0~ 60 ℃.
Platinum black material ElectRode with Glass shell, Measurement range 2-20000μS/cm, MiniDIN 8 core connector, suitable for a variety of Conductivity Meters.