Fluorescent light box

The fluorescent light box simulates a daylight environment using built-in fluorescent tubes of specific wavelengths. Based on the principle of luminescence from excited fluorescent materials, it is used in the printing and textile industries to compare color consistency and detect color differences or fading of materials during quality inspection.
Selection
When selecting, pay attention to whether the color temperature and color rendering index of the light tubes meet industry standards. The structure of the box should ensure uniform light shielding, and the operation interface should be simple. Consider matching the size of the object to be tested with the observation area, the lifespan and replacement cost of the light tubes, the stability of the working voltage, and the response speed of after-sales maintenance.

Terms

Standards

Instruments

Using LED Illuminant and 45/0 illumination conditions, Measurement range 0~ 199.9, resolution 0.1, can detect Fluorescent Whitening Agent and measure increased whiteness, Repeatability ≤ 0.3.

$ 417.00

Repeatability of 0.2 for measurement of diffuse reflection factor using 457 nm blue wavelength can detect Fluorescent Whitening Agent and calculate fluorescence whiteness value, which is suitable for surface whiteness analysis of various materials.

$ 554.00

It can measure the blue light diffuse reflection factor R457, analyze the fluorescent whitening agent, and print the results directly with a built-in micro-printer, repeatability error ≤ 0.1, support Opacity and light absorption coefficient measurement.

$ 1348.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illumination up to 3000LX, life more than 10,000 hours, uniform irradiation surface and no stroboscopic, flexible adjustment of light box position and angle according to test requirements.

$ 12305.00

With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.

$ 106.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Using R457 whiteness formula, blue light whiteness and fluorescence whiteness can be measured simultaneously, Repeatability ≤ 0.3, Operating temperature 5~ 35 ℃, optical path design is simple to ensure measurement accuracy and Repeatability.

$ 432.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

R457 blue light whiteness formula, Measurement range 0~ 199.9%, resolution 0.1, Basis Weight measurement of whiteness of fluorescent whitening objects and paper Opacity, suitable for a variety of materials surface flat samples.

$ 332.00

Built-in mobile slide table can move the camera front and rear, high display finger no stroboscopic LED Illuminant Color temperature is stable, the illuminance is adjustable, the back plate of the box can post 712mm * 400mm test card to provide a uniform lighting environment.

$ 4592.00

R457 blue light whiteness formula, Measurement range 0~ 100%, resolution 0.1, Repeatability ≤ 0.3, suitable for fluorescent whitening objects and paper Opacity measurement.

$ 490.00

Special sealing material is used to improve light protection, and the test results are accurate and stable; the bottom detection design is not affected by the angle, and the data is reliable; the detection limit is less than or equal to 1.0 CFU/ml, the detection time is 1-60 seconds, and the integrated box is portable.

$ 735.00

Special sealing material is used to improve light avoidance, and the detection results are accurate and stable; the bottom detection design is not affected by the angle; the detection accuracy reaches 1X10-16mol ATP, the detection range is 0-9999 RLU, and the integrated portable box design.

$ 627.00

It can measure the blue light diffuse reflection factor (R457) and fluorescence whiteness, use d/o illumination observation geometry conditions, test hole diaMeter 30mm, can analyze whether the material contains fluorescent whitening agent and measure a variety of Optical inspection coefficients.

$ 1348.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illuminance adjustment range 0-3000LX, life of more than 10,000 hours, uniform irradiation without stroboscopic.

$ 7464.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Key Technical Points for Determining Arsenic and Mercury in Water Using Atomic Fluorescence Spectrophotometry
This article introduces the key techniques for determining arsenic and mercury in water using an atomic fluorescence spectrometer. The experiment requires attention to safety precautions, regular maintenance of the instrument, and proper disposal of waste liquids.
Phosphor films and quantum dot coatings are uniformly applied using a coating machine.
This article introduces the significance of phosphor films and quantum dot coatings in optoelectronics and display technologies, highlighting that their performance depends on the uniformity, thickness, and density of the coatings.