Stainless Steel Viscosity Flow Cup

The stainless steel viscosity cup reflects viscosity by measuring the time it takes for the fluid to completely flow out from the small hole at the bottom of the cup; the longer the time, the higher the viscosity. It is used for rapid viscosity testing of liquids such as coatings and inks, and is suitable for both on-site and laboratory use.
Selection
When selecting, consider the viscosity range of the liquid being measured to match the aperture specifications of the cup. Stainless steel material is corrosion-resistant and suitable for most liquids. Choose the corresponding model according to standard requirements, such as Ford cups, and ensure the operating temperature meets the working conditions. Regular calibration is necessary to guarantee consistent measurements.

Terms

Instruments

The stainless steel material is durable and easy to clean, the inner wall of the Cup body is smooth to ensure the stability of Flow velocity, the diaMeter of the precision machining flow hole is 4mm, and the viscosity measurement range is 80~ 700cSt, which meets the requirements of multi-industry standards.

$ 190.00

Using 5mm flow hole design, the measurement viscosity range of 91~ 326cSt, aluminum alloy Cup body with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Made of stainless steel, with a flow hole diaMeter of 6mm and a viscosity range of 134-685mm ²/s, it is suitable for standard viscosity testing, and the flow time is controlled between 30 and 100 seconds.

$ 143.00

Made of stainless steel, with a flow hole diaMeter of 3.0 +/- 0.01mm and a viscosity range of 7-40mm ²/s, it is suitable for testing the outflow time of Newtonian or near-Newtonian liquids and meets ISO and GB standards.

$ 143.00

3Mm flow hole design, measurement of 7~ 42cSt viscosity range, suitable for Newton type liquid outflow time test, the Cup body is light and durable.

$ 170.00

Stainless steel material corrosion resistance, flow hole diaMeter 4mm, viscosity range 96~ 683cSt, outflow time 25~ 150s, with a unique serial number for quality control.

$ 581.00

Made of stainless steel, the diaMeter of the flow hole is 5mm, the Cup height is 74mm, and the viscosity is calculated by measuring the liquid outflow time, which meets international standards and has a unique serial number.

$ 559.00

Portable design with long stainless steel handle for easy operation. Outflow aperture 5.8mm, can measure 200-1200cSt viscosity range, corresponding to outflow time 30-100 seconds. Cup body aluminum alloy with stainless steel nozzle, both lightweight and corrosion resistance.

$ 285.00

The stainless steel material is durable, the inner wall of the Cup body is smooth to ensure stable Flow velocity, the diaMeter of the flow hole is 2mm, and the viscosity range of 70cSt can be measured. Precision machining ensures measurement accuracy.

$ 190.00

Nozzle of stainless steel with anodic oxidation aluminum Cup body, diaMeter of flow hole 6mm, viscosity measurement range of 22-2000cSt, suitable for rapid consistency determination of Newtonian behavior liquid.

$ 388.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

The 1mm-8mm pore size filter can be replaced to meet the viscosity range test of 96~ 683cSt; the annular groove of the Cup mouth is designed to store overflowing liquids, and the Cup body is easy to clean without sinkage. It is equipped with a stainless steel filter positioner.

$ 403.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, aperture 1.90mm, viscosity measurement range of 10~ 35cSt, flow time of 55~ 100 seconds, suitable for liquid viscosity evaluation.

$ 130.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.