Ink specific gravity bottle

The ink specific gravity bottle determines the density by measuring the ratio of the mass of ink to the mass of water in a fixed volume. It is used to control ink formulation and printing adaptability, and is employed for routine density testing in ink production and printing workshops.
Selection
When selecting, pay attention to the capacity specifications matching the sample volume, the material's resistance to ink corrosion, and clear, easy-to-read scales. Consider the temperature compensation function, the sealing performance of the bottle stopper, and whether a dedicated constant-temperature water bath is included. The ease of operation affects testing efficiency.
material
Cup volume
Calibrated certificate

Terms

Standards

Instruments

50Ml volume stainless-steelbeaker body, equipped with hollow structure Balance hammer filled with lead particles to adjust the weight, in line with national standards designed to ensure measurement accuracy, suitable for a variety of liquid specific gravity detection.

$ 106.00

Made of stainless steel to ensure durability, equipped with hollow structure Balance hammer filled with lead particles to adjust weight, Cup volume 100ml in line with national standards design, suitable for a variety of liquid specific gravity determination.

$ 106.00

Made of stainless steel, the Cup has a volume of 50 ml and can withstand an internal pressure of 10.3 bar. It is suitable for the determination of specific gravity of various Coatings and auxiliary materials. It is easy to operate and meets international standards.

$ 128.00

Using copper nickel plating material, volume 37ml, in line with GB/T6750 standard, equilibrium hammer is hollow structure and filled with lead particles to adjust the weight, suitable for Coating and auxiliary materials, oil and other liquids specific gravity determination.

$ 106.00

Using 5cm ³ standard measurement hammer volume, the accuracy of 0.001g, through the V-shaped groove placed riding code recovery equilibrate, can quickly and accurately measurement of liquid specific gravity.

$ 193.00

With large TFT backlight color screen and automatic temperature compensation function, urine specific gravity Measurement range 1.000~ 1.050, accuracy +/- 0.001, anti-light interference and IP65 waterproof and dustproof verification.

$ 304.00

Measurement range of serum protein 0~ 14g/dl and urine specific gravity 1.000~ 1.060, accuracy of +/- 0.1 and +/- 0.001, support automatic temperature compensation and anti-light interference design, ensure stability and reliability.

$ 304.00

With automatic temperature compensation function, support serum protein 0-14g/dl and cat urine specific gravity 000-1.060 measurement, large TFT color screen display clearly, anti-light interference design to adapt to a variety of environments.

$ 304.00

The high-toughness knife body enhances the strength of use, the log handle with open bottle cap and hanging hole is designed to be user-friendly, and the total length of the knife is 290mm and the length of the knife is 170mm to meet a variety of ink adjustment needs.

$ 80.00

High toughness knife body material to improve the use of strength, log handle with open cap and hanging hole design user-friendly, total length of 350mm knife length 230mm to meet a variety of ink needs.

$ 81.00

The high-toughness knife body material enhances the strength of use. The log handle with bottle opening cap and hanging hole design is more user-friendly. The total length is 265mm and the knife length is 145mm. The specifications are practical.

$ 79.00

Using high toughness knife body material, total length 242mm, knife length 142mm, log handle with bottle cap and hanging hole design, improve the use of strength and easy operation.

$ 78.00

The high-toughness knife body material enhances the strength of use. The log handle is designed with an open bottle cap and a hanging hole. The total length of the knife is 320mm and the length of the knife is 200mm. The humanized design is easy to operate.

$ 81.00

The high toughness knife body design enhances the use strength, the log handle is equipped with bottle opening function and hanging hole, the total length is 415mm and the knife length is 295mm, which is suitable for the preparation of paint inks.

$ 83.00

The high-toughness knife body material is used to improve the use strength. The log handle is designed with the function of opening the bottle cap. The total length of the knife body is 485mm and the length of the knife is 365mm. The humanized hanging hole is easy to store.

$ 84.00

Articles

The Printability Tester Simulates the Effects of Different Printing Pressures on Offset Ink Transfer Rate.
This paper investigates how the printability tester simulates the effect of different pressures on ink transfer rate in offset printing.
Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
The Application of Contact Angle Measurement Instruments in the Study of the Relationship Between Ink Printing Wettability and Substrate Surface Tension
This article introduces how a contact angle measuring instrument is used to study the relationship between wettability and substrate surface tension in ink printing. It first explains the principle, assessing the degree of wettability through the size of the contact angle, where an angle less than 90 degrees indicates good wettability.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Standard Procedure for Printability Tester in Evaluating Ink Transfer Performance
This article introduces the standard procedure for evaluating ink transfer performance using a printability tester. The transfer performance of ink directly affects print quality, and standardized operations can enhance the reliability of test results.