Electrically Heated Constant Incubator

The electric thermostatic incubator maintains a constant internal temperature through an electric heater and temperature control system, and is used for experiments requiring stable temperature environments, such as microbial cultivation and seed germination. The incubator body is constructed with thermal insulation materials to minimize heat loss, and the temperature fluctuation range is typically controlled within ±0.5℃.
Selection
When selecting, pay attention to whether the temperature range meets experimental needs, and check the temperature uniformity and fluctuation indicators inside the chamber. Consider whether the inner chamber material is corrosion-resistant, and whether the observation window design facilitates observation. Confirm the temperature control accuracy and safety features, including over-temperature protection. Choose an appropriate volume based on the available space, and consider energy consumption and ease of daily maintenance.

Terms

Standards

Instruments

Temperature range RT + 5~ 99 ℃, Temperature Fluctuation +/- 0.5 ℃, stainless steel liner, beaker hole can be arbitrarily changed in size, over-temperature sound and light tracking alarm to protect the sample.

$ 317.00

Temperature control accuracy +/- 0.3 ℃, resolution 0.1 ℃, mirror stainless steel liner for easy cleaning, silicone sealing ring to ensure high sealing, microcomputer controller provides stable and reliable operation.

$ 658.00

Microcomputer controller to achieve 0.1 ℃ resolution temperature control, mirror stainless steel liner easy to clean, equipped with silicone sealing ring to ensure the high sealing of the studio, over-temperature alarm function to improve the use of safety.

$ 362.00

Mirror stainless steel liner for easy cleaning, Temperature range 5 ℃~ 65 ℃ and Fluctuation +/- 0.3 ℃, microcomputer controller to ensure stable and reliable temperature, silicone sealing ring to ensure high sealing.

$ 535.00

The microcomputer controller is used to achieve accurate temperature control, Fluctuation is only +/- 0.3 ℃, Mirror stainless steel liner is easy to clean, Silicone sealing ring ensures high sealing of the studio, liner size 400 × 400 × 500mm.

$ 435.00

The equilibrate refrigeration technology makes the temperature fluctuation small, equipped with fluorine-free R134 refrigerant to achieve energy saving and environmental protection, high temperature control accuracy and constant humidity, liner mirror stainless steel material is easy to clean and maintain, and the volume is 100L to meet the needs of various experiments.

$ 1466.00

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.

$ 222.00

Fluorine-free design, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5 %~ +/- 8% RH, with over-temperature, leakage, Sensor fault multiple alarm protection functions to ensure safe operation of the experiment.

$ 1229.00

Equipped with intelligent Touchscreen controller and ultrasonic humidifier, Temperature Fluctuation +/- 0.5 ℃, Humidity Fluctuation +/- 5% RH, supports programmable control and a variety of safety protection functions, suitable for accurate environment simulation.

$ 1716.00

Environmentally friendly refrigerant design, Temperature Uniformity +/- 1 ° C, Humidity Fluctuation +/- 5% RH, equipped with intelligent Touchscreen controller and ultrasonic humidifier, supports programmable control and a variety of safety protection functions.

$ 4133.00

Using stainless steel liner, beaker hole can be arbitrarily changed size, temperature control accuracy +/- 0.5 ℃, with over-temperature sound and light tracking alarm function to ensure the safety and reliability of the sample.

$ 275.00

The fluorine-free design has low energy consumption, temperature uniformity of +/- 1 ° C and humidity fluctuation of +/- 5% RH, and is equipped with observation windows and lighting for easy monitoring. It supports programmable control and a variety of safety protection functions to ensure the stability and reliability of the experiment.

$ 5692.00

The air circulation design makes the temperature distribution uniform, the temperature control fluctuation is less than 0.5 ℃, the internal non-uniformity is about 1.0 ℃, with thermostatic timing and self-tuning functions, easy to operate and easy to clean.

$ 1332.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Pendulum Impact Tester Evaluates Impact Strength of Glass Fiber Reinforced Nylon
This article introduces the use of a pendulum impact tester to evaluate the impact strength of glass fiber reinforced nylon. The test is based on the principle of energy conservation, where the energy absorbed by the material is calculated by measuring the height difference of the pendulum before and after impacting the specimen, thereby quantifying its impact resistance.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Peel strength tester measures the peel force of hot melt adhesive resin.
The peel strength tester is used to measure the adhesive properties of hot melt adhesive resins, simulating the actual peeling process by recording changes in force values through constant-speed stretching.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Method for Determining Peel Strength of Hot Melt Adhesives Using an Electronic Tensile Tester
This article introduces the standard method for determining the peel strength of hot melt adhesives using an electronic tensile testing machine. The test employs a 180° peel mode, where a sample coated with hot melt adhesive is clamped in the machine's fixtures and peeled at a constant speed. The peel strength is calculated based on the recorded force variations.
Constant Temperature and Humidity Chamber Testing for Environmental Adaptability of Hot Melt Adhesive
This article introduces the method of testing the environmental adaptability of hot melt adhesive using a constant temperature and humidity chamber. The performance of hot melt adhesive is easily affected by temperature and humidity, and the purpose of the test is to evaluate its stability under different climatic conditions.