Spray-coated steel plate thickness Gauge

The spray-coated steel plate thickness gauge utilizes magnetic induction or eddy current principles to measure coating thickness by detecting changes in the electromagnetic field between the probe and the substrate. It is used to measure the thickness of spray-coated layers on steel plates, ensuring coating uniformity. It is applied in quality control for spray coating processes in metal products, appliance casings, and similar applications.
Selection
When selecting a spray-coated steel plate thickness gauge, consider the substrate type: magnetic induction type for iron-based materials and eddy current type for non-iron-based materials. Choose the measurement range based on the coating thickness, with 0-5mm being the conventional option. Ensure the probe size is suitable for curved surface measurements and that the device includes temperature compensation to adapt to workshop environments. Verify the instrument's calibration certificate and error range.

Terms

Standards

Instruments

Measurement range 0.65-400 mm, the highest accuracy is +/- 0.04mm, supports four measurement modes, Data storage 3000 groups, high-speed measurement up to 10 times/second, suitable for a variety of metal materials.

$ 835.00

Equipped with double spray guns to achieve uniform lame plating, the lifting range of the spray gun is adjustable from 10-500mm, the integrated air filtrate adjustment system supports magnetic or vacuum panel fixing, and improves the coating test Repeatability.

$ 67560.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measurement range with 0.01mm high resolution and 0.65-400 mm width supports Probe automatic identification and multiple Measurement modes, which can penetrate the thickness of the coating measurement substrate and realize the data freezing display.

$ 1610.00

With coating penetration measurement capability, resolution up to 0.01mm, Measurement range 0.65-400 mm, support Probe automatic identification and zero calibrate, provide standard and MIN Minimum two Measurement modes.

$ 1351.00

Measurement accuracy of 0.1μm using Hall principle and magnetic eddy current technology, equipped with a 2-inch color display and Ruby Probe, supports automatic matrix mode switching and statistical functions, and a dustproof and waterproof design enhances durability.

$ 1460.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Designed for specific types of thickness Gauges, it provides accurate Adjustment and adopts standard diaphragm structure to ensure accurate transmission of thickness measuring instruments and improve the repeatability of test results.

$ 110.00

Hall and magnetic eddy current principle to achieve dual mode measurement, accuracy of +/- (1μm + 2% reading), equipped with wear-resistant Ruby Probe and automatic flip screen, Measurement speed ≥ 100 times/minute, support statistical function.

$ 1072.00

Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.

$ 146.00

Range 20-370 microns, accuracy 10 microns, stainless steel corrosion resistance, hexagonal design with 24 scales, suitable for different Coating thickness measurement.

$ 231.00

Using Hall and magnetic eddy current dual principle, Measurement accuracy +/- (1μm + 2% reading), equipped with wear-resistant ruby Probe, support automatic matrix switching and statistical functions, Operating temperature 0~ 50 ℃.

$ 971.00

Using a formed pRoduction process, the film thickness is 100 microns, the application width is 300mm, and the stainless steel material ensures durability and Spreader uniformity.

$ 178.00

Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.

$ 119.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.