Portable Acid-Base Concentration Meter

Portable pH meters measure the concentration of hydrogen ions in a solution through electrodes, converting chemical signals into electrical signal readings. They are used for rapid on-site detection of liquid acidity or alkalinity and are suitable for applications such as industrial process control, wastewater monitoring, and environmental testing.
Selection
When selecting, consider that the measurement range should cover the requirements, the accuracy should meet the usage scenarios, and the electrode material should be compatible with the characteristics of the measured liquid. Pay attention to the instrument's protection rating and operating temperature range to ensure on-site applicability. Check auxiliary features such as calibration functions and data storage.

Terms

Standards

Instruments

The samples were treated by acid-base cooking method, and 6 samples could be measured each time. The repeatability error of the absolute value of crude fiber content below 10% did not exceed 0.4%, and the determination time was about 100 minutes.

$ 912.00

Supports multiple titration types and can store up to 100 titration methods. With a five-point pH calibrate 、 +/- 0.001 pH accuracy and a waterproof body, it can be connected to the Automatic sampler for efficient analysis.

$ 16265.00

Supports multiple titration types and Direct Measurement modes with five-point calibrated and 0.001mL resolution Burette, automated setup for Sample injectors, optimized desktop space and waterproof and durable design.

$ 9759.00

Support dynamic titration and preset endpoints and other modes, titration analysis Repeatability of 0.20%, Potential Measurement range -1800.0~ 1800.0mV, can store 200 sets of results and comply with GLP specifications.

$ 4066.00

It has 0.20% titration analysis Repeatability, supports dynamic titration and other modes, adopts PWM modulation and stirring technology implementation software speed regulation, can store 50 sets of titration results and support firmware upgrade and expansion functions.

$ 3002.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

Measurement range 0.00-2 ppm, accuracy +/- 0.04ppm, based on LED Illuminant and Color reaction principle, suitable for low concentration water quality detection.

$ 215.00

Measurement range 0.0-15 ppm, accuracy +/- 0.3ppm +/- 5% reading, using LED@525nm Illuminant, based on amino acid method for rapid detection of phosphoric acid salts, easy to operate and suitable for laboratory and field.

$ 209.00

Adapted to BNC interface pH ElectRode, supports 0.0-14 pH range calibrate, adjustable dose relay configuration is higher or lower than the user set point dosing, with timeout dosing protection function, the delay time is adjustable by 5-30 minutes.

$ 480.00

Using 525nm LED Illuminant, Measurement range 0.0-30 ppm, accuracy +/- 1.0ppm, based on amino acid method to achieve high Sensitivity phosphoric acid salt detection, suitable for a variety of water quality environments.

$ 215.00

Using 525nm LED Illuminant to ensure Stability, Measurement range 0-200ppb, accuracy +/- 5ppb, support ascorbic acid detection, with Automatic calibration verification function.

$ 215.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F.S, Response Time ≤ 30S, support a variety of signal output and remote alarm functions, with explosion-proof structure and intelligent Sensor technology.

$ 912.00

With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.

$ 106.00

Measurement accuracy up to +/- 0.05pH, Repeatability +/- 0.03, support 0-70 ℃ temperature compensation range, equipped with 3.7V rechargeable lithium battery, LCD large screen dual display design for easy reading.

$ 115.00

Measurement accuracy up to +/- 0.05PH, Repeatability +/- 0.03PH, equipped with LCD large screen display, support data retention and automatic temperature compensation function, easy and reliable operation.

$ 105.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
Key points for measuring the pH of water-based ink with a pH meter
This article introduces the key steps for measuring the acidity or alkalinity of water-based inks using a pH meter.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How to Choose Between IPX3 and IPX7 for a Rain Test Chamber? Understand the Rating Comparison Table and You'll Know
The rain test chamber is used to simulate product waterproof testing, with its core being the IP protection rating. IPX3 represents protection against spraying water, simulating rain splashes through a swinging pipe spray, suitable for outdoor lighting fixtures, etc. IPX7 represents protection against short-term immersion, simulating water submersion through soaking, suitable for portable devices.