Portable Digital Turbidity Meter

The portable digital turbidity meter measures the turbidity of liquids using the principle of light scattering. It illuminates the sample with a light source, detects the intensity of the scattered light, and converts it into a numerical value for display. It is used for on-site rapid detection of water quality, paint, or ink suspension concentrations, helping to monitor production processes and emission standards.

Instruments

With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.

$ 2505.00

Simultaneous measurement of 7 water quality paraMeters, turbidity Measurement range 0-50NTU, accuracy +/- 5%, in line with USEPA 180.1 standard, with chroma compensation and Illuminant automatic compensation function, reducing interference without frequent calibrating.

$ 2363.00

High Accuracy Optical Path System to Ensure Measurement Correctness and Repeatability, Measurement range 0~ 6.000MCF, Zero drift +/- 1.5%, Support Multi-turbidity Unit Selection, Circuit Stable and Long Illuminant Life.

$ 683.00

Using EPA custom Illuminant and chroma compensation technology, Measurement range 0.00-4000 NTU, minimum detection limit < 0.02NTU, support automatic range conversion and multiple calibrate modes to ensure the accuracy of low turbidity measurement.

$ 3527.00

With 0.00-1000 FNU multi-range measurement capability, using IR LED Infrared source, supporting automatic range conversion and 200 sets of Data storage, with a minimum detection limit of 0.1FNU, equipped with T.I.S electronic tag identification system.

$ 2203.00

Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.

$ 3878.00

Measurement range 0~ 400NTU, resolution 0.01, with low drift circuit and long life Illuminant, support AC and DC power supply, compact and lightweight design for portable use.

$ 396.00

Measurement range 0~ 20NTU, resolution 0.01, with unique positioning structure and High Accuracy optical path system, to ensure measurement accuracy and Repeatability, support AC and DC power supply, low power consumption design for portable use.

$ 215.00

Using 90 ° scattered light principle, Measurement range 0-200NTU, resolution up to 0.01NTU, with LCD liquid crystal display and AC/DC dual-use function, support automatic shutdown.

$ 211.00

Measurement principle of 90 ° scattered light, Measurement range 0~ 400NTU, resolution 0.01, High Accuracy Optical Path System and Stable Circuit, Support Multi-turbidity Unit switch, with print interface to ensure long-term reliable work.

$ 453.00

Using the principle of scattered light, the measurement range is 0-400NTU, the resolution is up to 0.01NTU, with average measurement mode and data storage function, convenient and reliable operation.

$ 259.00

The principle of scattered light is used for measurement turbidity, the measurement range is 0-200NTU, the resolution is 0.01NTU, the linearity is good and the operation is convenient, and it is suitable for a variety of water quality testing scenarios.

$ 262.00

Maxwell turbidity unit measurement of bacterial concentration, resolution 0.001 MCF, range 0-6MCF, with High Accuracy optical path system and low drift circuit, can store 20 records to ensure measurement accuracy and Repeatability.

$ 519.00

Using 90 ° scattered light principle, Measurement range 0-1000NTU, resolution 0.1NTU, support 7 point correction, weight only 0.5kg easy to carry, good linearity and reliable data.

$ 244.00

The use of LCD backlit LCD screen makes the reading comfortable and unaffected by light, High Accuracy optical path system to ensure measurement accuracy and Repeatability, Measurement range 0~ 6.000MCF, Repeatability +/- 1.5% F. S, can work stably for a long time.

$ 767.00

Articles

Turbidity meter selection: Basis for choosing light source type and measurement accuracy.
This article mainly introduces how to select a turbidity meter based on its light source type and measurement accuracy.
How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How to Choose Between IPX3 and IPX7 for a Rain Test Chamber? Understand the Rating Comparison Table and You'll Know
The rain test chamber is used to simulate product waterproof testing, with its core being the IP protection rating. IPX3 represents protection against spraying water, simulating rain splashes through a swinging pipe spray, suitable for outdoor lighting fixtures, etc. IPX7 represents protection against short-term immersion, simulating water submersion through soaking, suitable for portable devices.