Micro Moisture Content Analyzer

The micro-moisture analyzer detects the moisture content in samples using the Karl Fischer titration method. The reagent reacts quantitatively with the moisture, and the instrument measures changes in electrical signals to calculate the water content. It is used for moisture monitoring during the production process of materials such as coatings and inks to ensure stable product quality.
Selection
When selecting, consider matching the sample properties with the detection method. The coulometric method is suitable for trace moisture, while the volumetric method is more appropriate for higher concentrations. Ensure that the instrument's measurement range and accuracy meet the requirements, and comprehensively evaluate factors such as ease of operation, reagent consumption, and maintenance costs.

Terms

Standards

Instruments

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using electromagnetic wave scanning technology, high frequency scanning depth 50mm, Measurement range 0-99.9%, Response Time 1 second, no contact can be measured without damage to the internal moisture content of the object.

$ 225.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Measurement range 3μg~ 150mg, sensitive valve 0.1μg, Precision up to +/- 0.3%, automatic detection of electrolysis and measurement circuit, suitable for a variety of sample analysis.

$ 1910.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

Measurement range 5μg~ 100mg, Precision of moisture determination up to +/- 0.3%, results can be obtained in one minute, automatic tracking control of electrolysis current, reliable and easy to use.

$ 1518.00

Measurement range 0~ 50%, resolution 0.1, can simultaneously measure Moisture content and Ambient Temperature, stylus and host separation design for easy operation, low power LCD display.

$ 140.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using low-frequency signal transmission technology, the measurement depth is up to 20mm, and the humidity distribution map is displayed in real time through Bluetooth connection APP, and the extension Rod can be selected to facilitate large-area measurement.

$ 1009.00

Using pyrolysis weight principle design, moisture readability of 0.01%, heating temperature up to 200 ℃, equipped with 5 inch Touchscreen and German HBM Sensor, support automatic manual timing three test modes.

$ 545.00

Conductivity Detector measurement principle, measurement range 0~ 84%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation function, portable design weight only 203 grams.

$ 143.00

Temperature range RT +~ 180 ℃, the fastest few minutes to complete the measurement. With automatic alarm and Draft Shield design, support moisture and Solid content conversion at the same time, Test accuracy of 0.1%.

$ 420.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Moisture Analyzer Combined with Karl Fischer Method for Measuring Moisture Content in Resin Solvents.
This article introduces the use of the Karl Fischer method in conjunction with a moisture analyzer to measure the water content in resin solvents.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.