Portable COD Detector

The portable COD detector employs the chemical digestion colorimetric method, which measures absorbance after heating the sample and reagents, directly converting it into chemical oxygen demand values. It is used for rapid on-site determination of organic pollutant levels in water bodies and is suitable for scenarios such as wastewater treatment plants and river monitoring.
Selection
When selecting, focus on whether the detection range matches the water body type, and ensure the digestion temperature and time comply with standard methods. Check that the protection rating is suitable for field environments, and that reagent storage conditions are convenient for portability. The operation interface should be simple and support data export functionality.

Terms

Standards

Instruments

The separate design of digestion and determination does not affect the accuracy, COD digestion is completed in 15 minutes, 30 standard Linear dispersion and 199 sets of data can be saved, 4-16 water sample batches are supported, and IP65 waterproof and dustproof design is adopted.

$ 1366.00

Colorimetric integrated tube design, no need to transfer liquid, support more than 10 measurements to take the average value, measurement error ≤ +/- 5%, Repeatability ≤ +/- 5%, built-in two COD detection methods, can expand a variety of water quality paraMeter detection.

$ 2526.00

Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.

$ 267.00

Optical inspection system using imported cold Illuminant and narrow band interference, Optical inspection stability is less than 0.002A/20min, digestion temperature accuracy +/- 0.5 ℃, support COD and ammonia nitrogen dual paraMeter measurement, can save multiple standard Linear dispersion and data.

$ 1548.00

Measurement range 0.00~ 14.00, accuracy +/- 0.05, Stability +/- 0.03, support 0~ 60 ℃ temperature compensation, portable and lightweight only 205g, suitable for a variety of environments.

$ 156.00

Colorimetric digestion integrated tube design, no need to transfer liquid; the water sample for more than 10 measurements to take the average value, reduce the error; built-in two COD detection methods, Measurement range 0-20000mg/L.

$ 4688.00

Using sealing catalytic digestion and Colorimetry measurement, the measurement range is 5~ 2000mg/L, the repeability is less than or equal to 3%, and the batch processing of 12 water samples is supported, and the operation is simple and time-saving.

$ 1114.00

Using 420nm and 620nm dual wavelength LED Illuminant, supports high and low concentration COD detection, Measurement range 0-1500mg/L can be extended to 15000mg/L, built-in 2000 data storage and automatic printer.

$ 2073.00

With standard COD, total phosphorus, total nitrogen working procedures, support custom temperature and time; using new temperature control algorithm, heating uniform and fast, heating up to 165 ℃ only 12 minutes, temperature control accuracy +/- 1 ℃; one-button operation, with automatic alarm and transparent protective cover.

$ 767.00

Using sealing catalytic digestion technology, the measurement range is 5~ 2000mg/L, the repeability is less than or equal to 3%, the batch processing of 16 water samples is supported, and the PID automatic temperature control and data storage function are provided.

$ 1355.00

Colorimetric integrated tube design, sample digestion and result reading share a tube, no need to transfer liquid; more than 10 measurements of water samples and removal of abnormal values are averaged to reduce errors; built-in two COD detection methods, Measurement range 0-20000mg/L, detection limit as low as 2mg/L.

$ 3075.00

It can simultaneously read up to 8 water quality parameters, equipped with a 9000mAh large-capacity battery, supports Sensor address modification and temperature, zero point, slope calibrating, which is convenient for long-term operation and Facility Management on site.

$ 2526.00

Adopt air condensation technology instead of water condensation, Temperature control accuracy +/- 2 ℃, equipped with 12 heating holes, heating up to 170 ℃ time is less than 30 minutes, support segmented timing function.

$ 464.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Conductivity Detector measurement principle, measurement range 0~ 95%, resolution of 0.1%, Response Time of only 1 second, with temperature compensation and automatic shutdown function, portable design weight of about 175 grams for on-site use.

$ 144.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How to Choose Between IPX3 and IPX7 for a Rain Test Chamber? Understand the Rating Comparison Table and You'll Know
The rain test chamber is used to simulate product waterproof testing, with its core being the IP protection rating. IPX3 represents protection against spraying water, simulating rain splashes through a swinging pipe spray, suitable for outdoor lighting fixtures, etc. IPX7 represents protection against short-term immersion, simulating water submersion through soaking, suitable for portable devices.