Paint thick film coater

The thick film Coater applies paint evenly onto the substrate surface through a blade to form a wet film of specified thickness, simulating the application effect of thick coatings in laboratory settings. This equipment can test the leveling, hiding power, and other properties of coatings, making it suitable for quality control and formulation development in architectural and industrial coatings.
Selection
When selecting, consider that the coating thickness range must cover the testing requirements, and substrate compatibility includes materials like metal and glass. The operation mode—manual or automatic—should be determined based on the frequency of use. Pay attention to the wear resistance of the scraper material and the flatness of the equipment, while also verifying that the sample size matches the equipment specifications.

Terms

Standards

Instruments

It can measure the ability of the paint film to deform with the substrate without damage. It is equipped with a shaft Rod with a diaMeter of 50mm and 100mm.

$ 309.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

The drying process of paint film and putty film can be accurately measured by using circular track needle design, equipped with four different radius needle (R0.25/0.5/1.0/1 mm), and the track period is 24h/r.

$ 223.00

The device uses 20.70ml pump volume and 2kg weight load, which can accurately measure the flow spread diffusion diaMeter of the sample under fixed pressure, ensuring the consistency test, repeability and accuracy.

$ 186.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0-10.5 mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 404.00

Impact height of 120 cm, hammer mass 1000g, no secondary rebound phenomenon after impact, punch diaMeter 16mm, can accurately determine the impact strength of the paint film.

$ 370.00

The pressure range of the probe is 50~ 250N, the diaMeter of the rubber probe is 40mm, and the degree of paint film chalking is evaluated by comparing the imprint of the photo paper with the standard sample, which is suitable for the detection of various environmental factors.

$ 444.00

Using photo paper smooth surface combination technology, observing the imprint after applying a uniform load, the pressure range of the probe is 50-250N, and the diaMeter of the rubber probe is Φ 40mm, which can accurately evaluate the chalking grade of the paint film.

$ 433.00

Wire-wound design, film thickness 120 microns, total length 37.5cm, effective application width 25.5cm, stainless steel material to ensure durability and uniform Spreader.

$ 173.00

Konig and Persoz swing bars are used, Konig swing period is 1.4s, Persoz swing period is 1s, and the number of swing angles is automatically recorded, which is suitable for accurate determination of paint film Hardness.

$ 662.00

Hand type easy to operate, load 1000g, standard 6B-6H pencil, suitable for film hardness testing, test temperature 23 +/- 2 ℃ and Humidity 50 +/- 5% environment.

$ 341.00

Wire-wound design can be prepared 160 micron wet film thickness, corrosion resistant stainless steel material, suitable for high viscosity test and not easy to block, longer service life.

$ 160.00

Wire-wound structure design, wet film thickness 160 microns, suitable for high viscosity test is not easy to block, 303 stainless steel material corrosion resistance, longer service life.

$ 186.00

Measurement range of 50~ 7600 μm, error +/- 3%, suitable for thick soft coatings such as polyurea and asphalt neoprene, providing accurate thickness detection.

$ 3226.00

The bending diaMeter of putty film cracking peeling is tested by bending test plate, and the shaft Rod size is 50mm and 100mm. It is suitable for 0.2-0 mm thick tinplate substrate, and the operation is simple and reliable.

$ 228.00

Articles

Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Operation Tips for Laboratory-Scale Hot Melt Adhesive Coating Machines
This article introduces the key operational points of a laboratory-scale hot melt adhesive coater. The equipment is primarily used in laboratories to apply hot melt adhesives uniformly onto substrates, supporting the research, development, and testing of adhesives.
Application of Continuous Coating Machine for Lithium Battery Electrode Preparation in Electrode R&D
The laboratory continuous coater is a key piece of equipment in lithium battery electrode research and development, used to simulate mass production coating processes. By precisely controlling parameters such as coating speed, thickness, and tension, it helps researchers optimize slurry formulations and coating procedures.
How to Coat High-Viscosity Slurry – Parameter Setting Tips for Blade Coaters
This article primarily discusses the parameter setting techniques for high-viscosity slurries on blade coaters. High-viscosity slurries exhibit characteristics such as shear thinning, so it is essential to leverage shear effects during coating to facilitate slurry spreading. After coating, the viscosity should recover quickly to prevent sagging.
Common Troubleshooting for Wire Bar Coater: Solving Issues of Streaking and Uneven Thickness
This article mainly introduces solutions to two common faults in the operation of the wire rod coater—coating streaks and uneven coating thickness.
Roll-to-roll coater enables continuous preparation of flexible electronic materials.
Roll-to-roll coating is a continuous production process that involves uniformly applying functional slurry onto a flexible substrate, followed by drying and curing to form a functional film.
What are some cost-effective alternatives to roll-to-roll coaters for the early stages of flexible film R&D when the investment is too high?
The investment in roll-to-roll coating machines is too high. What are some cost-effective alternatives for the early stages of flexible film research and development? Among blade coating, spin coating, and spray coating, which one would you choose?
Coating Process of Slurries with Different Viscosities on Vacuum Adsorption Coating Machines
This article explores the process adaptability of slurries with different viscosities on vacuum adsorption coating machines. The slurries are categorized into low, medium, and high viscosity, and their flow characteristics during the coating process, along with key process control points, are discussed respectively.
The working principle of laboratory wire rod coaters and methods for controlling coating thickness
The laboratory wire rod coater is a precision instrument used to prepare uniform, thickness-controllable wet film coatings on substrate surfaces. Its core components include a coating rod, a flat coating platform, clamps for securing the substrate, and a mechanical system that drives the coating rod to move at a constant speed.