The programmable constant temperature and humidity test chamber precisely controls temperature and humidity within a sealed space through its refrigeration/heating system and humidification/dehumidification system. It is used to simulate the performance changes of products under different environmental conditions, commonly applied in scenarios such as material aging tests and reliability verification of electronic components.
Selection
When selecting, consider a temperature range covering -70℃ to 150℃ and a humidity range of 20% to 98%. Pay attention to uniformity of ±0.5℃/±2% RH and fluctuation of ±0.2℃. Choose based on internal volume, and note the stainless steel inner chamber material and compressor brand. Confirm that it is equipped with USB data export and fault recording functions.

Terms

Instruments

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.

$ 9152.00

Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and 100 group program storage function.

$ 5799.00

Using multi-stage programmable PID controller and equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and a variety of protection functions.

$ 3630.00

Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control accuracy +/- 1.0 ℃, humidity control deviation +/- 3% RH, equipped with independent temperature limit alarm system, support 100 sets of programs 1000 cycle steps to ensure the stability and safety of the test process.

$ 10533.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Humidity Control Range 35-95% RH, Input Power 8050W, Fluorine-free design, multi-stage programmable PID controller and imported 304 mirror stainless steel liner, with independent temperature limit alarm system.

$ 9447.00

Using multi-stage programmable PID controller, Temperature range -20~ 100 ℃, with independent temperature limit alarm system and P.I.D automatic calculation function, to ensure accurate and stable control of heat preservation Humidity, safe and reliable.

$ 7969.00

Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.

$ 5307.00

Temperature range -20~ 100 ℃, Temperature resolution 0.1 ℃, using TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuations, with 100 sets of program capacity and a variety of Safety protection functions.

$ 4419.00

With -40~ 150 ℃ Temperature range and 20~ 98% Humidity control, environmentally friendly refrigerant and double-decked airtight design, support multi-stage program editing and fast temperature Humidity control, easy to move and observe.

$ 8465.00

Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.

$ 6194.00

Adopt TMHM equilibrate Conditioning method, temperature fluctuation +/- 1.0 ℃, humidity deviation +/- 3% RH; with 100 sets of program capacity and P.I.D automatic calculation function, ensure stable and uniform heat preservation Humidity, support multi-stage programmable operation.

$ 2841.00

With -60~ 150 ℃ wide temperature range and 30~ 98% RH humidity control, multi-wing air supply cycle to ensure uniform temperature and humidity, 7.0 inch large screen programmable controller supports 100 sets of programs to improve test efficiency and accuracy.

$ 8142.00

Temperature range -40~ 150 ℃ and Humidity control 30~ 95% R. H, using programmable multi-stage control and independent temperature limit alarm system, equipped with test holes and can be pulled out of the water Tank for easy operation.

$ 9843.00

Articles

Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Constant Temperature and Humidity Chamber Testing for Environmental Adaptability of Hot Melt Adhesive
This article introduces the method of testing the environmental adaptability of hot melt adhesive using a constant temperature and humidity chamber. The performance of hot melt adhesive is easily affected by temperature and humidity, and the purpose of the test is to evaluate its stability under different climatic conditions.
Constant Temperature and Humidity Chamber Testing for Ink Environmental Adaptability
This article introduces the method of testing the environmental adaptability of ink using a constant temperature and humidity chamber. Ink is prone to issues such as adhesion, discoloration, or reduced adhesion when exposed to changes in temperature and humidity.
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.
Application of Constant Temperature and Humidity Chambers in the Electronics Industry
A constant temperature and humidity chamber is a device capable of precisely controlling temperature and humidity, used to simulate various environmental conditions that electronic products may encounter. In the electronics industry, it is primarily employed to test the reliability of components, finished products, and processes, such as evaluating material aging or performance changes through high-temperature and high-humidity tests.
Common Operational Fault Analysis and Daily Maintenance Strategies for Constant Temperature and Humidity Test Chambers
This paper focuses on typical issues faced by constant temperature and humidity test chambers in practical applications, such as temperature deviations, abnormal humidity control, and blockages in the water circuit system. It delves into the underlying causes of these faults and proposes a maintenance framework centered on daily inspections and standardized operations.
Comparison of Humidity Control Methods in Constant Temperature and Humidity Test Chambers: Wet and Dry Bulb Method vs. Electronic Sensor Method
This article will explain the principles, advantages, and disadvantages of these two methods to help you make a more informed decision when selecting equipment.
Technical Selection and Application of Constant Temperature and Humidity Chambers
This article primarily discusses how to select and use a constant temperature and humidity chamber. It is mainly used to test the performance of materials and products under varying temperature and humidity conditions.