Powder Moisture Content Tester

The powder moisture content analyzer uses the heating and drying method to heat the sample until moisture evaporates, and calculates the moisture content based on the change in mass. It is used to detect the moisture content of materials such as powders and granules, and to control production quality in industries like coatings and plastics.
Selection
When selecting a powder moisture analyzer, consider the sample type and moisture range, match the heating method and temperature control accuracy. Pay attention to the instrument's measurement speed and repeatability, ensure it is easy to operate and meets daily testing requirements.

Terms

Standards

Instruments

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using electromagnetic wave scanning technology, high frequency scanning depth 50mm, Measurement range 0-99.9%, Response Time 1 second, no contact can be measured without damage to the internal moisture content of the object.

$ 225.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Measurement range 0~ 50%, resolution 0.1, can simultaneously measure Moisture content and Ambient Temperature, stylus and host separation design for easy operation, low power LCD display.

$ 140.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using low-frequency signal transmission technology, the measurement depth is up to 20mm, and the humidity distribution map is displayed in real time through Bluetooth connection APP, and the extension Rod can be selected to facilitate large-area measurement.

$ 1009.00

Using pyrolysis weight principle design, moisture readability of 0.01%, heating temperature up to 200 ℃, equipped with 5 inch Touchscreen and German HBM Sensor, support automatic manual timing three test modes.

$ 545.00

Conductivity Detector measurement principle, measurement range 0~ 84%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation function, portable design weight only 203 grams.

$ 143.00

Temperature range RT +~ 180 ℃, the fastest few minutes to complete the measurement. With automatic alarm and Draft Shield design, support moisture and Solid content conversion at the same time, Test accuracy of 0.1%.

$ 420.00

Articles

High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Hall flowmeter measures the flowability of spray powder
This article introduces how a Hall flowmeter measures the flowability of spray powder. It uses a standard funnel to measure the time required for a certain mass of powder to flow out under gravity—the shorter the time, the better the flowability.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Sand Falling Test Apparatus for Measuring the Wear Resistance of Powder Coatings
The sand falling test instrument determines the wear resistance of powder coatings by simulating sand particle impact. During the test, abrasive material falls vertically from a specified height, continuously scouring the coating until the substrate is exposed. The wear resistance is evaluated based on the mass of abrasive material consumed.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Pendulum hardness tester measures the damping hardness of powder coatings.
This article introduces the method of testing the damping hardness of powder coatings using a pendulum hardness tester. The test is based on the principle of energy attenuation, where the hardness is reflected by the time it takes for the amplitude of the pendulum to decay as it swings on the coating surface, with a longer time indicating a harder coating.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Rapid prediction of coating chalking and gloss loss failure through UV aging tests.
This article introduces how UV aging tests can quickly predict the failure of paint chalking and loss of gloss. The test accelerates coating aging in the laboratory by simulating solar ultraviolet light, temperature, and humidity, while observing phenomena such as chalking and loss of gloss.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Phosphor films and quantum dot coatings are uniformly applied using a coating machine.
This article introduces the significance of phosphor films and quantum dot coatings in optoelectronics and display technologies, highlighting that their performance depends on the uniformity, thickness, and density of the coatings.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
The Key Role of Apparent Density Meters in Assessing Powder Flowability.
This article discusses how a bulk density tester is used to evaluate the flowability of powders. Powder flowability is crucial in production. The instrument measures the bulk density and tapped density, then calculates the compressibility index and Hausner ratio. These two parameters directly reflect the quality of powder flow.
The combination of bulk density tester and angle of repose tester provides a one-stop solution for powder flowability testing.
This article introduces a method for comprehensively evaluating powder flowability in powder engineering by combining the use of an apparent density tester and an angle of repose tester. Apparent density reflects the packing characteristics of the powder, while the angle of repose indicates its ease of flow.