Paint color stick

The paint color stick is a small rod coated with a specific color of paint, used to determine color matching by comparing the color difference between the sample and the color stick. It is employed for quick color comparison during paint production and application to avoid color discrepancy issues.
Selection
When selecting paint color sticks, it is essential to consider whether the color coverage meets common color ranges, the material should be resistant to solvent corrosion, the size should conform to handheld habits, the coating should be uniform and free of defects, and it should match industry-standard color charts.

Terms

Standards

Instruments

The instrument uses 241 +/- 6mm tire uniform rolling detection, wet film thickness 200um +/- 20um, every 30 seconds, repeability test, accurate determination of non-stick tire drying time, suitable for marking Coating quality control.

$ 231.00

The tire size of the instrument is Φ 241 +/- 6mm, weight 15.8 +/- 0.2kg, dedicated to marking Coating drying time test, easy to operate, accurate and reliable results.

$ 196.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

Temperature sensitive discoloration paint after overheating Color from white to transparent, irreversible discoloration, suitable for rough oil surface, Measuring temperature 60 ℃, Net weight of plastic bottles 100 grams.

$ 131.00

With 15 °, 45 °, 110 ° three-angle measurement function, can simultaneously obtain Color data, flicker and particle grade; built-in automatic white calibrating, no human intervention; with stable long-life LED Illuminant, the service life is up to 10 years.

$ 11100.00

It can measure the ability of the paint film to deform with the substrate without damage. It is equipped with a shaft Rod with a diaMeter of 50mm and 100mm.

$ 309.00

Using ruby probe and digital Probe technology, Measurement range 0-3500 μm, error ≤ +/- ( 3% H + 2 μm), 0.5 seconds fast measurement, can identify iron powder putty layer and a variety of substrate types.

$ 180.00

The drying process of paint film and putty film can be accurately measured by using circular track needle design, equipped with four different radius needle (R0.25/0.5/1.0/1 mm), and the track period is 24h/r.

$ 223.00

Built-in camera to accurately locate the measurement area, UV Illuminant can measure fluorescent color, Repeatability Delta E * ab ≤ 0.06, supports 26 kinds of Illuminant and 30 + kinds of chroma indicators to meet various measurement needs.

$ 1929.00

Temperature sensitive discoloration paint after overheating Color from white to transparent, discoloration effect depends on the object surface Color, Measuring temperature 65 ℃, suitable for rough oil surface use.

$ 131.00

Impact height of 120 cm, hammer mass 1000g, no secondary rebound phenomenon after impact, punch diaMeter 16mm, can accurately determine the impact strength of the paint film.

$ 370.00

Adopt all directions swing vibration mode to ensure that the paint is fully mixed, Vibration Frequency 550 times/min, equipped with 0-15 minute timing function, suitable for 80-240mm barrel height range.

$ 1171.00

The adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel ≥ 80mm. The integrity of the paint film was evaluated by seven grades, and the operation was simple and conformed to the GB/T1720 standard.

$ 444.00

Built-in camera to accurately locate the measurement area, equipped with UV Illuminant to achieve fluorescent color measurement, Repeatability Delta E * ab ≤ 0.06, support more than 30 chroma indicators and 26 kinds of Illuminant conditions, Automatic calibration operation is convenient.

$ 1655.00

Using photo paper smooth surface combination technology, observing the imprint after applying a uniform load, the pressure range of the probe is 50-250N, and the diaMeter of the rubber probe is Φ 40mm, which can accurately evaluate the chalking grade of the paint film.

$ 433.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.
This article introduces how to use a wear testing machine to evaluate the wear resistance of wood and floor coatings.