DIN Viscosity Measurement Cup

DIN viscosity cups determine viscosity by measuring the time it takes for a fluid to flow out of a standard orifice, with the time being proportional to the viscosity. They are used for quality control of fluids such as coatings and inks, offering simple operation and suitability for rapid on-site testing.
Selection
When selecting a DIN viscosity cup, consider the viscosity range of the fluid being measured and match it with the corresponding cup number. Choose the aperture size according to standard requirements. The material must be resistant to chemical corrosion. The usage environment determines whether a temperature compensation function is necessary.

Terms

Standards

Instruments

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Made of stainless steel, the flow hole diaMeter is 2mm, according to DIN 53211, providing accurate viscosity measurement for Newtonian or near newtonian fluids.

$ 581.00

In line with DIN 53211 standard, the outflow time is 25~ 150s, the viscosity range is 15~ 30cSt, and the aluminum alloy Cup body and stainless steel nozzle are used to quickly test low viscosity liquids.

$ 135.00

Using aluminum alloy Cup body and stainless steel nozzle, the outflow aperture is 4mm, the viscosity measurement range is 112~ 685cSt, and the outflow time is 25~ 150s, which is suitable for rapid testing of sample viscosity on the pRoduction line.

$ 135.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

Conform to DIN 53211 standard, evaluate viscosity by measuring 100ml liquid outflow time, 4mm pore size design is suitable for 112~ 685cSt viscosity range, outflow time is 25~ 150 seconds, anodic oxidation aluminum alloy Cup body corrosion resistance.

$ 130.00

Adopting anodic oxidation aluminum alloy Cup body and stainless steel nozzle, the outflow aperture is 6mm, the viscosity measurement range is 550~ 1500cSt, and the outflow time is 25~ 150 seconds, which is suitable for rapid viscosity testing of pRoduction lines.

$ 135.00

The 1mm-8mm pore size filter can be replaced to meet the viscosity range test of 96~ 683cSt; the annular groove of the Cup mouth is designed to store overflowing liquids, and the Cup body is easy to clean without sinkage. It is equipped with a stainless steel filter positioner.

$ 403.00

Aperture 4.12mm, viscosity measurement range of 70~ 370cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Using anodic oxidation aluminum alloy Cup body and stainless steel nozzle, the outflow aperture is 8mm, and the viscosity measurement range is 1200~ 3000cSt, which is suitable for the pRoduction line to quickly test the sample viscosity, and the outflow time is controlled at 25~ 150 seconds.

$ 135.00

Outflow aperture 1.9mm, viscosity measurement range of 10~ 35cSt, aluminum alloy Cup body and stainless steel pore structure durable, in line with ASTM D1200 standard.

$ 167.00

Measurement range is 7~ 40cst, flow hole diaMeter is 3mm, using copper Cup body, in line with ISO2431 standard, suitable for viscosity measurement and equipped with bracket.

$ 196.00

Adopt replaceable filter design, support 1-8mm aperture selection; Cup annular groove can store overflowing liquid, Cup wall has no clean dead angle; comply with DIN53211 standard, with unique serial number for easy tracking.

$ 441.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.