Thermal Shock High Temperature Test Chamber

The thermal shock test chamber rapidly switches between high and low temperature environments, subjecting samples to drastic temperature changes within a short period. It is used to assess the tolerance of materials under sudden temperature variations and is commonly applied in quality verification for products such as electronic components, coatings, and plastics.
Selection
When selecting, ensure the temperature range covers the testing standards, the transition time meets the requirements for rapid temperature changes, and the chamber volume accommodates the sample size. Pay attention to the temperature uniformity and fluctuation indicators, and confirm that the equipment meets the reliability and ease of maintenance for daily testing.

Terms

Standards

Instruments

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.

$ 16840.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Temperature range -40 ℃ to + 150 ℃, the temperature conversion time is only 10 seconds, using PID full digital automatic Control system, can quickly detect the material in the extremely high temperature and low temperature continuous environment resistance and thermal expansion and contraction changes.

$ 17303.00

Using three-box equipment structure, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy reaches +/- 0.5 ℃, and the air circuit switching method realizes fast Thermal Shock, which is suitable for material physical and chemical change testing.

$ 38156.00

Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. Equipped with HFC environmentally friendly refrigerant and ultra-low temperature freezing system, the cooling is fast and efficient.

$ 16840.00

With three-box structure design, the temperature conversion time is only 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, and it is equipped with touch graphic operation interface and air passage switching system to achieve fast and stable Thermal Shock testing.

$ 36381.00

The three-box structure design is adopted, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, the Thermal Shock test is realized through the air circuit switching, and the touch graphic operation interface is equipped to simplify the operation process.

$ 16759.00

Two-box mobile structure, air pressure driven test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL, IEC and other specifications, with paperless recording and real-time Linear dispersion display function.

$ 17985.00

Adopting a three-box structure design, the temperature recovery time does not exceed 5 minutes, and the temperature conversion is completed within 10 seconds. It is equipped with a touch-sensitive graphic operation interface and an air path switching system to achieve fast and stable Thermal Shock testing.

$ 12660.00

The three-box heat storage and cold storage structure is adopted, the temperature conversion time is ≤ 10 seconds, and the temperature recovery time is ≤ 5 minutes, which can realize the rapid Impact test of high temperature 150 ℃ to low temperature -55 ℃, and meet the environmental adaptability verification of the extreme temperature of the material.

$ 18437.00

The three-box structure is used to achieve a completely static test zone, with a temperature conversion time of ≤ 10 seconds and a temperature recovery of ≤ 5 minutes. It has an Impact range of 150 ° C in the high temperature zone and -55 ° C in the low temperature zone, meeting the needs of rapid temperature change testing.

$ 24133.00

With two-box mobile Impact structure, the temperature recovery time is less than 5 minutes, and the conversion time is only 10 seconds. Equipped with rigid polyurethane foam insulation material, it has ultra-low temperature thermal conductivity and waterproof performance, and supports programmed temperature control.

$ 14564.00

The three-box structure is used to realize the static test sample, the strong cooling hot air circuit switching technology, the temperature conversion time is less than or equal to 10 seconds, the temperature recovery time is less than or equal to 5 minutes, and the temperature control function is independent in the high temperature zone, the low temperature zone and the test zone.

$ 15032.00