Rubber Temperature Cycling Test Chamber

The rubber high and low temperature test chamber simulates environmental temperature changes through heating and cooling systems, keeping rubber samples at set temperatures for specified durations to observe their performance changes. It is used to test the heat resistance, cold resistance, and stability of rubber materials under high or low temperature conditions, commonly applied in quality control and research and development testing of rubber product manufacturing.
Selection
When selecting, consider that the temperature range should cover the extreme limits of rubber usage, with minimal uniformity error. The heating and cooling rates should match the testing requirements, and the chamber material should be corrosion-resistant and easy to clean. Ensure comprehensive safety protection features and an intuitive operating interface. Determine the volume size based on the actual sample dimensions and testing standards.

Terms

Standards

Instruments

Adopt stainless steel liner and superfine Glass cotton insulation, equipped with multi-layer conductive film observation window and silicone rubber sealing. Temperature control accuracy +/- 0.5 ℃, humidity fluctuation +/- 2% RH, with independent over-temperature protection and interlocking safety device.

$ 7948.00

Adopt stainless steel liner and superfine Glass cotton insulation, equipped with multi-layer conductive film observation window and silicone rubber test hole. Temperature control accuracy +/- 0.5 ℃, humidity fluctuation +/- 2% RH, with independent over-temperature protection and multiple safety devices.

$ 10820.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Adopt stainless steel liner and ultra-fine Glass cotton insulation structure, equipped with multi-layer conductive film observation window and silicone rubber sealing. Temperature control accuracy +/- 0.5 ℃, humidity fluctuation +/- 2% RH, with PID control and safety protection system.

$ 8739.00

Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, using ultra-fine Glass insulation cotton and double-decked silicone rubber sealing, equipped with independent over-temperature protector and multi-layer conductive film observation window to ensure stable and safe testing.

$ 8255.00

Adopt stainless steel liner and ultra-fine Glass insulation cotton structure, equipped with multi-layer conductive film observation window and silicone rubber test hole. Temperature control accuracy +/- 0.5 ℃, humidity uniformity +/- 2-3% R.H., with PID control and safety protection system.

$ 6334.00

Temperature range -20~ 150 ℃, humidity control 30~ 98% R.H., stainless steel liner and ultra-fine Glass insulation cotton, equipped with independent over-temperature protection and multi-layer conductive film observation window to ensure stable and reliable testing.

$ 7771.00

Temperature range -30~ 150 ℃ and Temperature Uniformity ≤ +/- 2 ℃, using multi-layer conductive film observation window anti-frost design, equipped with independent over-temperature protector and solid state relay control to ensure stable operation.

$ 7948.00

Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with 100 sets of program capacity and RS-232/485 communication function.

$ 12402.00

Temperature range -20~ 150 ℃ and humidity control 30~ 98% R.H., using PID control and solid state relay to ensure stability, multi-layer Glass observation window frost-proof design, support a variety of safety protection functions.

$ 6189.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

With -40~ 150 ℃ wide temperature control and 30~ 98% humidity range, using French Taikang Compressor and multi-wing air supply circulation, high temperature and humidity uniformity, support 100 groups of program editing, improve test efficiency.

$ 14112.00

SUS304 stainless steel inner box and double insulation structure, equipped with 360 degree swirl/spin sample holder and precise ozone concentration control, temperature fluctuation +/- 0.5 ℃, support static dynamic tensile test, suitable for rubber durability research.

$ 5899.00

Using French Taikang fully enclosed Compressor, equipped with multi-wing air supply circulation system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2-3% R.H, improve test accuracy and efficiency.

$ 7754.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
Rotating Rubber Wheel Abrasion Tester for Determination of Coating Taber Abrasion Index
This article introduces the method for determining the Taber abrasion resistance index of coatings using a rotating rubber wheel abrasion tester.
Shore hardness tester measures the hardness of rubber sealing rings.
This article introduces the method of measuring the hardness of rubber sealing rings using a Shore durometer. The Shore durometer presses a needle into the rubber surface under spring force and converts the indentation depth into a hardness value, commonly using the A scale.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Rubber abrasion tester measures tire wear resistance.
The rubber abrasion tester evaluates wear resistance by simulating the friction between tires and road surfaces. It uses a grinding wheel to rub against rubber specimens under set conditions, measuring mass loss and converting it to volume loss to assess material performance.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Ozone Aging Test Chamber Evaluates Crack Resistance of Rubber
This article introduces how an ozone aging test chamber is used to evaluate the crack resistance of rubber. Ozone is a common factor that causes rubber aging. The test chamber simulates an ozone-containing environment, applies strain to rubber samples, and accelerates their aging process.
UV Aging Test Machine Evaluates Outdoor Lifespan of Rubber
This article introduces how ultraviolet aging test chambers assess the service life of rubber in outdoor environments. Rubber exposed outdoors is affected by factors such as sunlight, temperature, and humidity, leading to a gradual decline in its performance.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Insulation resistance tester measures rubber sealing gaskets.
This article introduces the method of using an insulation resistance tester to inspect rubber sealing gaskets.
Universal material testing machine measures the tensile modulus of rubber.
This article introduces how to measure the tensile modulus of rubber using a universal material testing machine. The tensile modulus is an important parameter that measures the ability of rubber to resist stretching under small deformations.
Selection of Wear Testing Machine: Types of Abrasion Wheels and Load Setting Methods
The test results of the wear testing machine primarily depend on the type of grinding wheel and the load setting. Grinding wheels include rubber wheels, abrasive wheels, wire wheels, and fiber wheels, among others. The selection should be matched based on the material characteristics and the actual wear scenario.