Overview
The Bante520-DL Portable Conductivity Meter is a standard Portable Conductivity Meter for outdoor measurement of liquid conductivity. The meter has a 1 to 3 point button Adjustment to set Electrode Constant and temperature compensation factor. Measurement accuracy is 0.5% F.S.
Features
1. Standard Portable Conductivity Meter with large LCD screen.
2.1 to 3 point button calibrated to automatically identify Conductivity detector standard solution.
3. Optional Electrode constant (0.1/1/10), standardized temperature (20 or 25 ° C), linear/nonlinear and pure water temperature compensation mode.
4. Automatic temperature compensation to ensure accurate measurement within the full range.
5. Automatic end point lock, keep stable Measured value for easy browsing or recording.
6. The system menu can customize 10 function parameters such as the number of calibrated points, temperature unit, data locking mode, and automatic shutdown.
7. One-click reset (Reset) automatically restores the meter to the factory default settings.
8. Extended memory can store up to 100 sets of measurement data.
9. USB Communication interface sends stored data to PC.
10. Multi-mode power supply solution (battery, Power Adapter, USB port of computer) to ensure smooth application of the instrument.
Principle
The Conductivity Meter uses the Conductivity detector Electrode measurement liquid conductivity, using automatic temperature compensation technology to ensure measurement accuracy. The meter supports manual or automatic temperature compensation, and the measurement process is optimized by calibrating point setting and Electrode constant selection.
Applications
Water quality monitoring, geological and ecological research, chilled down tower and boiler water, printing industry, swimming pools and spas, agriculture and aquaculture, aquariums, educational applications
Steps
1. Turn on the meter power.
2. Select Electrode constant and temperature compensation mode as needed.
3. Perform 1 to 3 point button calibrating to automatically identify Conductivity detector standard solution.
4. Electrode immersed in the liquid to be measured to begin measurement.
5. The instrument automatically performs temperature compensation and end point locking, and displays the stable Measured value.
6. Optional manual or automatic data lock mode to record data.
7. Send the stored data to the computer through the USB interface.
Notice
• Make sure the meter is properly calibrated before use.
• Select the appropriate Electrode constant and temperature compensation mode to adapt to different measurement environments.
• Avoid use in extreme temperatures or Humidity conditions to prevent accuracy.
• Regularly check the battery level, low battery level may cause measurement errors.
• Electrode cleaning to prevent contamination from affecting measurement results.
• Memory capacity when storing data to avoid overflow.
• Use the one-click reset function to restore the factory settings and clear all custom parameters.