$ 2628.00Ex works
Adopt 10-stage adjustable LED vertical Illuminant system, temperature control accuracy of +/- 1 ℃. Equipped with 99 cycle program setting function, support continuous operation, built-in mirror stainless steel liner for easy cleaning and maintenance.
Category : Incubator
Brand : HuiTai
SKU : NB024686
Service :The delivery and service By NBCLab.Com
HUITAI HGZ-400N light chamber is a professional equipment, widely used in microbial tissue cell fostering, seed germination, seedling test, plant cultivation and insect and small animal feeding, etc., can accurately simulate different environment climate conditions.
1. Large-screen LCD display, one-screen display of multiple sets of data, menu-style operation interface, simple to understand and easy to operate. 2. Use 134a without fluorine refrigerant, effective energy saving, environmental protection and health. 3. Mirror stainless steel liner, four corners and a half arc design is easy to clean, and the shelf spacing is adjustable. 4. The wind speed of the equipment fan is adjusted according to the speed and speed of the gear to prevent the sample from losing moisture too quickly. 5. The instrument control of the whole machine is placed in the upper left corner of the door panel, which is beautiful and elegant, saving space. 6. There is a 25mm diameter test hole on the left side, which is convenient for experimental operation and temperature measurement. 7. Adopt double-decked door structure, good thermal insulation performance, observation box does not affect the temperature. 8. The surface of the box is sand blasting, which is not easy to scratch and easy to clean. 9. Adopt brand Compressor, independently develop cooling system, prolong Compressor life. 10. Adopt JAKEL pipe flow circulating fan and unique air duct structure to ensure temperature uniformity in the box. 11. Standard LED light source, can be divided into 10 levels of dimming, vertical Illuminant, Illuminant board removable. 12. The microcomputer controls the temperature and illumination, and the temperature can be set differently day and night depending on the lighting. 13. PID control mode, accurate control of small fluctuations. 14. With 99 cycles, each cycle is divided into 30 segments, each of which is 99 hours and 59 minutes. 15. Supports long-term continuous operation. 16. Optional independent temperature limit alarm system, exceeding the limit temperature will automatically interrupt and sound and light alarm. 17. Optional USB or RS485 interface can be used to connect a printer or computer to record temperature parameters.
The light chamber precisely adjusts the temperature and illuminance through the microcomputer control system, and adopts the PID control mode to ensure that the temperature fluctuation is small. The device uses LED Illuminant for 10-level dimming to simulate the change of day and night light, and combines the JAKEL pipe flow circulating fan and unique air duct structure to achieve good air circulation and ensure the uniform and stable environment in the box.
Microbial tissue cell fostering, seed germination, seedling experiment, plant cultivation, insect and small animal feeding
1. Turn on the power supply and set the temperature and illumination parameters. 2. Adjust the fan wind speed gear as required. 3. Use the menu-style operation interface to program settings, and support multi-cycle cycles. 4. Place the sample on the adjustable shelf and remove the Illuminant plate if necessary. 5. Experimental operation and temperature measurement through the test hole. 6. Optional connection to a printer or computer to record data.
• Ambient Temperature should be maintained at 5~ 30 ℃. • Power frequency AC380V 50Hz before use. • Avoid temperature control below 4 ° C when there is no light or below 10 ° C when there is light. • Regularly clean liner and box surfaces to prevent contamination. • Pay attention to the wind speed adjustment of the fan during operation to prevent the loss of moisture from the sample. • When selecting an independent temperature limit alarm system, the temperature limit should be set correctly. • Long-term operation requires monitoring of equipment status to ensure safety.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.