$ 9755.00Ex works
Using stainless steel liner and ultra-fine fiberglass insulation, equipped with 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, support multi-stage programming and automatic correction function, improve test efficiency.
Category : High Low Temperature Test Chamber
Brand : ZKHS
SKU : NB026917
Service :The delivery and service By NBCLab.Com
GDJS-500B high and low temperature alternating damping heat test chamber is produced by ZKHS, suitable for aerospace products, information electronic Instruments, materials, electrical, electronic products and various electronic components in high and low temperature or heat and humidity environment inspection of its performance indicators. The equipment adopts advanced control system and refrigeration technology to ensure accurate and stable test environment.
1. The box is processed by numerical control machine tool, which is beautiful and easy to operate 2. The liner is imported stainless steel mirror plate, and the shell is sprayed with A3 steel plate, which has high cleanliness 3. The replenishment tank has automatic protection for water shortage, which is convenient for water source replenishment 4. Large observation window with lighting, clear observation of the situation in the box 5. The humidification system piping is separated from the control circuit board to improve safety 6. Waterways and circuit systems are door-opened for easy maintenance and repair 7. The box body insulation adopts ultra-fine fiberglass insulation cotton to reduce energy loss 8. The left side of the box is equipped with a test hole for external test lines 9. The temperature and humidity control instrument has a 7.0-inch large screen and supports Chinese and English interfaces 10. With 100 sets of programs and 1000 segments of 999 cycle steps capacity 11. The controller has a screen lock function to prevent accidental touch and shutdown 12. Supports RS-232 or RS-485 communication, and can design programs on the computer 13. With automatic calculation function, accurately correct temperature and humidity changes 14. The refrigerator adopts the original French "Taikang" fully enclosed Compressor 15. Multi-wing blower is used for strong air circulation, with uniform temperature and humidity distribution 16. The air circuit circulation design makes the temperature and humidity stabilize quickly, reducing the test cost
The test chamber precisely sets the temperature and humidity parameters through a programmable controller. The refrigeration system adopts a unit or binary low temperature circuit design, and cooperates with a multi-wing blower to achieve strong circulation to ensure uniform temperature and humidity in the test area. The heating, humidification and dehumidification systems work independently, and the environmental conditions are corrected in real time through automatic calculation function to achieve stable control.
Aerospace Products, Information Electronic Instruments, Materials, Electrical, Electronic Products, Various Electronic Components
GB/T10592-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、GB/T2423.4-2008、GJB150.3A-2009、GJB150.4A-2009
1. Turn on the power supply and check whether the voltage meets the requirements of AC220V +/- 10% or AC380V +/- 10% 2. Open the control panel, select the Chinese and English interface, and set the temperature and humidity program 3. Put the test sample into the studio to ensure stable placement 4. Connect the external test line to the test hole on the left side of the box (if necessary) 5. Start the device, the monitoring screen shows real-time operation Linear dispersion 6. After the test is completed, stop the equipment according to the program and take out the sample
• Operating Environment Temperature should be maintained at 5 ℃~ 30 ℃, humidity ≤ 85% R.H • Regularly check the water level of the replenishment tank to avoid protection shutdown due to water shortage • Make sure the power is disconnected during maintenance to avoid the risk of electric shock • Do not open the door frequently when the equipment is running, so as not to affect the temperature and humidity stability • Use a soft cloth when cleaning the box to avoid scratching the stainless steel surface • In case of over-temperature, water shortage and other alarms, check and troubleshoot immediately • If not used for a long time, the power supply should be cut off and the equipment should be kept drying
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.