Overview
BENTING CBGDW-1000L low/high temperature test chamber is a professional Environmental performance equipment, providing a wide temperature range control from -20 ° C to 150 ° C, suitable for high and low temperature performance testing of various products. The box adopts a cold plate paint outer box and a mirror stainless steel inner wall, equipped with a single hinged door, observation window and anti-condensation device to ensure the stability and visibility of the test process.
Features
1. Enclosure Material is cold plate paint, the inner wall is made of good mirror stainless steel plate
2. The box insulation material is fiberglass, effective insulation
3. Single hinged door design, with observation window, lighting and anti-condensation electric heating device
4. Control panel integrated controller display, U disk interface, RS232 communication interface and sound and light alarm
5. The refrigeration unit automatically adjusts the operating conditions, saving energy and high efficiency
6. The evaporator cooling capacity is switched by the solenoid valve for precise control
7. The power distribution system includes IO boards, transformers, relays, etc., which are safe and reliable
Principle
The low/high temperature test chamber drives the refrigeration unit and solenoid valve through the control system to achieve precise temperature regulation. The first-stage compression method is used in the range of 0 ° C to -40 ° C, and the binary cascade refrigeration is used in the range of -40 ° C to -70 ° C. Combined with Air-Cooled or Water-Cooled heat exchangers, it ensures rapid temperature rise and fall. The control system automatically optimizes the operation according to the set conditions, maintaining Temperature Fluctuation ≤ 0.5 ° C and Uniformity ≤ 2.0 ° C.
Applications
Electronics, automotive parts, materials research, aerospace components, chemical products
Steps
1. Connect the power supply and turn on the device switch.
2. Set the required temperature parameters through the control panel
3. Start the test program and monitor the running status
4. Turn off the device and disconnect the power after the test is completed
Notice
Prohibit testing for flammable, explosive, volatile, highly toxic, corrosive, and radioactive substances
• Make sure the equipment is well grounded to prevent electrical failures
• Regularly check the refrigeration system and drain holes to avoid clogging
• Pay attention to high and low temperature parts during operation to prevent burns or frostbite