Please contact customer service
Using dual array CMOS image sensor, Repeatability Delta E * ab is controlled within 0.01. Provide micropore aperture reflection measurement, compatible with SCI/SCE simultaneous fast measurement, with multiple Color Spaces and Observation Illuminants.
Category : Colorimeter
Brand : 3NH
SKU : NB039084
Service :The delivery and service By NBCLab.Com
Benchtop Colorimeter TS8216 is a Colorimeter developed by 3nh using its own spectroscopic core technology. It adopts a dual-array CMOS image sensor with high Sensitivity and a wide Light spectrum Response range for more accurate testing. TS8216 Benchtop Colorimeter Repeatability Delta E * ab is easily controlled within 0.01, and Inter-instrument Agreement Delta E * ab is controlled within 0.12. The data is stable and reliable, and can be used for accurate analysis and transmission of laboratory Color.
1. Micropore diameter: provide reflection: → 0.3mm/0.5mm/1mm (only one diameter is selected) Transmission: medium 8mm/4mm (only one diameter is selected), used for chroma control of small area reflection samples and small capacity transmission samples. 2, using the international common D/8 structure, compatible with SCI/SCE measurement, and support SCI + SCE simultaneous rapid measurement. 3. Dual Array CMOS Image Sensor: High Sensitivity and Wide Light spectrum Response Range Ensure Instrument Measurement speed, Accuracy, Stability and conformity. 4. Various Color measurement spaces, Various observation Illuminants: Provide CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, β xy, DIN Lab99 Color spaces, and D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30 Various observation Illuminants. 5, the use of a combination of Full Light spectrum LED Illuminant, UV Illuminant: Full-band Balanced LED Illuminant to ensure that there is sufficient Light spectrum distribution in the visible range, to avoid the white LED in a specific band of Light spectrum loss, to ensure the instrument Measurement speed and accuracy of measurement results, professional UV Illuminant to ensure more reliable UV testing. 6. Measurement verification report: Each TS8216 Benchtop Colorimeter has been verified and tested, and the instruments are verified according to the measurement standards of the trusted verification department. Traceability of measurement data to the National Measurement Institute to ensure the credibility of instrument test data. 7, industrial high definition Touchscreen, easy to use user interface: 7 inch industrial high definition Touchscreen, smooth control, simple and easy to use user interface makes the operation comfortable, convenient and easier to use. 8. Color management software: With SQCX quality management software, it is suitable for quality monitoring and Color data management in various industries. Digitize the user's Color management, compare Color differences, generate test reports, provide a variety of color space measurement data, and customize the customer's Color management work.
The instrument adopts concave grating spectroscopy technology, through the combination of full light spectrum LED Illuminant illumination samples, the dual-array CMOS image sensor receives the reflection or transmission of Light spectrum signals, and analyzes them in the 360~ 780nm Wavelength range, and calculates various chroma data of the samples.
Color analysis and transfer laboratory, plastic electronics, paints inks, Spinning & weaving garment printing, printing, paper, cosmetics, food
CIE No.15、GB/T 3978、GB 2893、GB/T 18833、ISO7724/1、ASTM E1164、DIN5033 Teil7
1. Instrument preheating and calibration. 2. Measurement mode (reflection or transmission) and corresponding caliber. 3. Select Measurement conditions such as Color Space and Available Light Sources. 4. Place the sample. 5 for measurement. 6. View, analyze data and generate reports through Touchscreen or supporting software.
• The instrument needs to be used in an operating environment of 0~ 40 ° C. • Storage Ambient Temperature -20~ 50 ℃. • Make sure the instrument is fully preheated and calibrated before measurement. • Select the appropriate measurement aperture and mode (reflection/transmission, SCI/SCE) according to the sample characteristics (e.g. area, state). • Accessories such as corresponding culture dishes should be used for transmission measurement. Measurement verification is performed regularly to ensure data accuracy. Illuminant lifetime may need to be evaluated after more than 5 years or 3 million measurements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.