Overview
YIHENG BLF-6K Centrifuge is a compact device with a Rotation speed of 6000 rpm and a noise of less than 50dB. It is small in size and beautiful in appearance. It is suitable for microtubule filtrating and rapid centrifugation. It can effectively prevent liquid wall hanging in centrifuge tubes. It adopts professional design concepts and manufacturing technology. It has a compact and firm structure and is ultra-quiet. It is widely used in scientific research laboratories.
Features
1. Ultra-quiet: using special motors, strong power, ultra-quiet, stable operation, noise is generally less than 50dB, and the maximum does not exceed 54dB;
2. Fast instantaneous acceleration: 90% of the maximum Rotation speed in 5 seconds;
3. Small vibration: a well-designed shock absorber that generates minimal vibration during operation.
4. Small size, large capacity: larger than the market equivalent product capacity, can hold up to 2ml × 6;
5. Easy to replace the rotor: the design is ingenious, making it easy to replace the rotor without any tools.
6. Large centrifugal force: the maximum relative centrifugal force can reach 5000G;
7. Fast shutdown: Designed with two shutdown methods, free shutdown takes no more than 15 seconds, and open the lid and brake shutdown takes only 3 seconds.
Principle
The BLF-6K Centrifuge uses a direct-drive motor for high-speed swirl/spin through automatic or constant speed control, generating centrifugal force for sample separation. Its shock absorber ensures smooth operation and fast and efficient acceleration and deceleration processes for microtubule filtrating and rapid centrifugation applications.
Applications
scientific research laboratory
Steps
1. Connect the power supply AC230V, 1A, 50/60Hz;
2. Install the rotor as needed and replace it without tools.
3. Place the sample tube with a Maximum capacity of 0.2ml * 8 tubes or 0.2ml octahedral tubes * 2 rows;
4. Speed range in automatic or constant mode, up to 6000rpm;
5. Start the equipment, and the acceleration time reaches 90% of the rated Rotation speed within 5 seconds;
6. After the operation is completed, choose the stop method: close the lid and stop freely for no more than 15 seconds, or open the lid and brake for only 3 seconds.
Notice
• Ensure that the power supply is AC230V, 1A, 50/60Hz, and check the fuse specification for 250v 0.5A before use;
• No tools are required to replace the rotor, but it is necessary to ensure that the installation is firm.
• Pay attention to the noise level during operation, generally less than 50dB.
• Select the appropriate centrifugal force and Rotation speed according to the sample requirements;
• When stopping, choose the braking mode of closing the lid or opening the lid according to the actual situation;
• Dimensions of the equipment are 175 * 148 * 118mm to ensure sufficient storage space.