| Product Name | 3NH YL4568 Non-contact ColoriMeter | 3NH YL4660 Non-contact ColoriMeter |
| Product Price | In coming | $7464.00 |
| Details | Details | |
| Model comparison | ||
| Sample type | Plane Powder Paste Liquid | Plane Powder Paste Liquid |
| Measurement aperture | Φ4mm Miscellaneous | Miscellaneous |
| Measurement Geometry | 45°/0 | 45°/0 |
| Color difference formula | ΔE*ab ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter) | ΔE*ab ΔE*uv ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter) |
| Parameter comparison | ||
| Optical inspection structure | 45/0 (45 ° annular uniform illumination 0 ° reception) | 45/0 (45 ring uniform illumination 0 ° reception) |
| spectroscopy | Concave grating spectroscopy | Concave grating spectroscopy |
| Sensor | 256 pixel dual array CMOS image sensor | 256 pixel dual array CMOS image sensor |
| Field of view | 2°/10° | 2°/10° |
| Illuminant | Light spectrum LED Illuminant, UV Illuminant | Light spectrum LED Illuminant |
| Illuminant life | More than 3 million measurements in 5 years | More than 3 million measurements in 5 years |
| UV Illuminant | contain | Yes. |
| Observational Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
| Wavelength range | 400~700nm | 400~700nm |
| wavelength interval | 10Nm output | 10nm |
| Measurement caliber | φ 20mm (can be customized φ 10mm, φ 4mm) | Φ20mm |
| Repeatability of chromatic value | Delta E * ab within 0.03 (after preheating, the average value of 30 whiteboard measurements at intervals of 5s) | Delta E * ab within 0.03 |
| Spectroscopic reflectance Repeatability | Standard Deviation within 0.1% (Measurement time 1.5 seconds in optimal test mode) | Standard Deviation Within 0.08% |
| Inter-instrument Agreement | Delta E * ab within 0.2 (BCRA series ⅱ 12 swatches measurement average) | Delta E * ab within 0.2 |
| Measurement time | Up to 0.2 seconds (a full measurement cycle of 200 milliseconds) | Fast mode about 1.0s (0.2~ 1.5s adjustable) |
| Reflectance measurement range | 0~200% | 0~200% |
| Measurement mode | Single measurement, average measurement (2~ 99 times) | Single measurement, average measurement (2~ 99 times) |
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Munsell,s-RGB,HunterLab,βxy,DIN Lab99 | CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB |
| Color difference formula | ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter),DINΔE99 | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter) |
| Whiteness/Yellowness/Blackness | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) |
| Tint/Metamerism | Metamerism Index MI | Metamerism Index MI |
| Colour fastness/force/coverage | Dip colour fastness, discoloration fastness, force, coverage | Dip colour fastness, discoloration fastness, force, coverage |
| Liquid/Transmission Special | Non-contact measurement of liquids, sauces, powders | |
| Software support | Software customization capabilities (additional customization capabilities need to be evaluated) | The PC-side software has powerful expansion functions |
| Data storage | 18,000 sample mode + quality control mode, 30,000 continuous statistical mode, no more than 48,000 in total | 40,000 sample mode + quality control mode; 10,000 continuous statistical mode |
| Interface | USB, Bluetooth ® 5.0 | USB/RS-232, Bluetooth 5.0 |
| display screen | TFT True Color 7inch, Capacitive Touchscreen | TFT True Color 7inch, Capacitive Touchscreen |
| display content | Light spectrum chart/data, sample chromatic value, color difference value/chart, Color simulation, pass/fail results, Display tolerance can be set | Light spectrum graph/data, sample chromatic value, color difference value/graph, chromaticity graph, Color simulation, pass/fail results, display tolerance can be set |
| Operating language | Simplified Chinese, Traditional Chinese, English | Simplified Chinese, Traditional Chinese, English |
| Operating temperature | 0~40℃ | 0~40℃ |
| Allowable relative humidity | 0~ 85% RH (no condensation) | 0~ 85% RH (no condensation) |
| Storage temperature | -20~50℃ | -20~50℃ |
| Storage Humidity | 0~ 85% RH (no condensation) | 0~ 85% RH (no condensation) |
| Power supply method | DC 24V, 3A Power Adapter | DC 24V, 3A Power Adapter |
| Dimension | 200 * 200 * 160Mm (Probe) | 330*250*370mm |
| Net weight | About 3Kg (Probe only) | About 10Kg |
| Optional accessories | φ 10mm, φ 4mm measurement diameter (customized) | |
| Special features | Non-contact measurement, can be used for fluorescence sample measurement, camera positioning, distance adjustment method is fixed height according to the actual sample | Non-contact measurement, test Probe and test sample non-contact test; built-in camera viewfinder positioning; sample height can be stored; manual/automatic distance adjustment |