Product Name 3NH YL4568 Non-contact ColoriMeter 3NH YL4660 Non-contact ColoriMeter
Product Price In coming $7464.00
Details Details
Model comparison
Sample type Plane Powder Paste Liquid Plane Powder Paste Liquid
Measurement aperture Φ4mm Miscellaneous Miscellaneous
Measurement Geometry 45°/0 45°/0
Color difference formula ΔE*ab ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter) ΔE*ab ΔE*uv ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter)
Parameter comparison
Optical inspection structure 45/0 (45 ° annular uniform illumination 0 ° reception) 45/0 (45 ring uniform illumination 0 ° reception)
spectroscopy Concave grating spectroscopy Concave grating spectroscopy
Sensor 256 pixel dual array CMOS image sensor 256 pixel dual array CMOS image sensor
Field of view 2°/10° 2°/10°
Illuminant Light spectrum LED Illuminant, UV Illuminant Light spectrum LED Illuminant
Illuminant life More than 3 million measurements in 5 years More than 3 million measurements in 5 years
UV Illuminant contain Yes.
Observational Illuminant D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30)
Wavelength range 400~700nm 400~700nm
wavelength interval 10Nm output 10nm
Measurement caliber φ 20mm (can be customized φ 10mm, φ 4mm) Φ20mm
Repeatability of chromatic value Delta E * ab within 0.03 (after preheating, the average value of 30 whiteboard measurements at intervals of 5s) Delta E * ab within 0.03
Spectroscopic reflectance Repeatability Standard Deviation within 0.1% (Measurement time 1.5 seconds in optimal test mode) Standard Deviation Within 0.08%
Inter-instrument Agreement Delta E * ab within 0.2 (BCRA series ⅱ 12 swatches measurement average) Delta E * ab within 0.2
Measurement time Up to 0.2 seconds (a full measurement cycle of 200 milliseconds) Fast mode about 1.0s (0.2~ 1.5s adjustable)
Reflectance measurement range 0~200% 0~200%
Measurement mode Single measurement, average measurement (2~ 99 times) Single measurement, average measurement (2~ 99 times)
Color space CIE LAB,XYZ,Yxy,LCh,CIE LUV,Munsell,s-RGB,HunterLab,βxy,DIN Lab99 CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB
Color difference formula ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter),DINΔE99 ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter)
Whiteness/Yellowness/Blackness WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313)
Tint/Metamerism Metamerism Index MI Metamerism Index MI
Colour fastness/force/coverage Dip colour fastness, discoloration fastness, force, coverage Dip colour fastness, discoloration fastness, force, coverage
Liquid/Transmission Special Non-contact measurement of liquids, sauces, powders
Software support Software customization capabilities (additional customization capabilities need to be evaluated) The PC-side software has powerful expansion functions
Data storage 18,000 sample mode + quality control mode, 30,000 continuous statistical mode, no more than 48,000 in total 40,000 sample mode + quality control mode; 10,000 continuous statistical mode
Interface USB, Bluetooth ® 5.0 USB/RS-232, Bluetooth 5.0
display screen TFT True Color 7inch, Capacitive Touchscreen TFT True Color 7inch, Capacitive Touchscreen
display content Light spectrum chart/data, sample chromatic value, color difference value/chart, Color simulation, pass/fail results, Display tolerance can be set Light spectrum graph/data, sample chromatic value, color difference value/graph, chromaticity graph, Color simulation, pass/fail results, display tolerance can be set
Operating language Simplified Chinese, Traditional Chinese, English Simplified Chinese, Traditional Chinese, English
Operating temperature 0~40℃ 0~40℃
Allowable relative humidity 0~ 85% RH (no condensation) 0~ 85% RH (no condensation)
Storage temperature -20~50℃ -20~50℃
Storage Humidity 0~ 85% RH (no condensation) 0~ 85% RH (no condensation)
Power supply method DC 24V, 3A Power Adapter DC 24V, 3A Power Adapter
Dimension 200 * 200 * 160Mm (Probe) 330*250*370mm
Net weight About 3Kg (Probe only) About 10Kg
Optional accessories φ 10mm, φ 4mm measurement diameter (customized)
Special features Non-contact measurement, can be used for fluorescence sample measurement, camera positioning, distance adjustment method is fixed height according to the actual sample Non-contact measurement, test Probe and test sample non-contact test; built-in camera viewfinder positioning; sample height can be stored; manual/automatic distance adjustment