Pin-Type Moisture Probe

The needle-type moisture meter measures moisture content by contacting the sample with a metal probe, utilizing the correlation between material moisture and conductivity or dielectric constant. It is used for rapid detection of the moisture content of granular and powdered solid materials and is employed on-site in industries such as grain, wood, and construction materials.
Selection
When selecting, consider matching the measurement range to the common moisture content of the material, ensuring the probe length is suitable for the sample thickness, and pay attention to the temperature compensation function. Check whether the calibration method is simple, and compare the measurement accuracy and response speed of different models. Choose between portable or fixed types based on the usage scenario, and confirm the corrosion resistance of the probe material.

Terms

Standards

Instruments

Measurement principle of resistance method, accuracy of +/- 1%, equipped with 610mm detachable long probe, can measure different depths of grain moisture, support voice broadcast and a variety of function settings, suitable for a variety of grain moisture detection.

$ 97.00

The guide rail type is easy to operate, the positioning pin ensures accuracy, the pressing device reduces errors, the sampling thickness is less than 1.0mm, the parallelism is less than 0.1mm, and a variety of standard samples can be cut.

$ 861.00

Conductivity Detector measurement principle, measurement range 0-80%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation and backlight display, easy to quickly detect on site.

$ 144.00

Using temperature and humidity compensation technology to improve measurement accuracy, probe Sensor can penetrate deep into the material, Measurement range 0.8-80%, Response Time is only 1 second, with error fine-tuning and Interface customization function.

$ 233.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

Equipped with fixed K-type stainless steel penetration Probe, Response Time 20 seconds, IP65 waterproof standard, with CAL Check ™ calibrate inspection and battery error prevention system to ensure accurate and reliable measurement.

$ 286.00

Using conductivity Measurement principle, can measure 0~ 80% moisture range, accuracy +/- (0.5% n + 1), with 240 data storage and USB/RS-232/Bluetooth communication function.

$ 235.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Measurement range 0-80%, accuracy +/- (0.5% n + 0.5% n), support USB/RS-232/Bluetooth Data output method.

$ 241.00

With split Probe design, equipped with F and N Probe, Measurement range 0~ 1500 microns, resolution 0.1 microns, automatic identification of substrate type, support for more than 60 readings per minute, Protection Rating IP65.

$ 1476.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Temperature and humidity compensation technology, measurement Precision +/- 0.5%, Response Time less than 1 second, with MAX Maximum hold and automatic shutdown function, optional single and double pin Sensor, easy to quickly detect on site.

$ 180.00

Using high frequency principle, the measurement range is 0-80%, the accuracy is 0.1/0, and the Response Time is 1 second. The probe type Sensor can penetrate deep into the material. The portable design weighs about 200 grams, which is suitable for on-site rapid detection.

$ 235.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.