High Temperature Furnace Temperature Tracer

The high-temperature furnace temperature tracker records the temperature change curve of objects during the heating process through built-in thermocouples, and is used to monitor the actual temperature distribution inside industrial furnaces. This instrument can accurately reflect the heating state of workpieces and verify whether the heating program meets requirements in processes such as paint curing and plastic molding.
Selection
When selecting, it is necessary to match the furnace size and temperature measurement range, ensuring the instrument's temperature tolerance limit exceeds the process temperature. Pay attention to sampling rate and accuracy indicators, and prioritize shell materials with good thermal insulation properties. Consider the compatibility of data interfaces to ensure the software can generate clear temperature curve reports.

Terms

Standards

Instruments

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the 30-segment programmable controller is used to realize automatic operation, the Furnace door sealing is good to ensure Temperature uniformity, the refractory brick Furnace and the resistance wire heating element are resistant to high temperature and have a long life.

$ 1815.00

High aluminum Furnace wear-resistant high temperature, 4-sided heating evenly; PID self-tuning temperature control accuracy +/- 2 ℃, over-temperature automatic protection; compact overall structure, convenient and safe operation.

$ 567.00

The maximum temperature is 1200 ℃, the Furnace volume is 2L, the microcomputer PID controller is used for precise temperature control, the door sealing design enhances Temperature uniformity, and the corrosion resistance refractory brick Furnace is durable.

$ 838.00

With 30 programmable control function, support heating or stay setting, stainless steel Furnace door and microcomputer PID controller, to ensure accurate and reliable temperature control, Furnace Temperature uniformity.

$ 1313.00

Using double-decked shell structure and aluminum oxide Furnace material, temperature control accuracy +/- 1 ℃, heating rate ≤ 20 ℃/min, temperature field Balance and energy saving, low surface temperature.

$ 6948.00

It only takes 25 minutes to heat up to 1200 ° C, the temperature control accuracy is +/- 1 ° C, the ceramic fiber Furnace and air insulation structure are used, the surface temperature is only about 50 ° C, and it has multi-step programming function.

$ 1947.00

Maximum temperature of 1700 ℃, Furnace volume of 12 liters, using silicon molybdenum Rod heating and aluminum oxide fiber Furnace to ensure uniform heating and durability, support inert or reducing gas environment, suitable for high temperature material processing.

$ 5979.00

Using ceramic fiber Furnace and air insulation structure, the surface temperature is only about 50 ℃. Heating to 1200 ℃ for less than 25 minutes, temperature control accuracy +/- 1 ℃, support multi-step program control.

$ 2048.00

The double-decked Furnace shell insulation design is adopted, and the shell is not hot; the Furnace temperature distribution uniformity is less than +/- 5 ° C, and the heating rate is ≥ 10 ° C/min; it has a nitrogen filling device to slow down oxidation and supports flexible setting of self-made temperature control programs.

$ 1019.00

Imported HRE ultra-high temperature alloy heating element, heating to 1200 ℃ less than 25 minutes, temperature control accuracy +/- 1 ℃, Furnace body and shell with air insulation structure, low surface temperature.

$ 1303.00

Maximum temperature 1000 ℃, temperature control accuracy 1 ℃, using high aluminum liner and upper and lower left and right 4-sided heating design, with 30 program settings and over-temperature protection function, uniform temperature in the Furnace.

$ 893.00

30L large-capacity Furnace with 1200 ℃ high temperature range, using refractory brick insulation material and intelligent PID temperature control system, with over-temperature protection and power-off recovery function, to ensure the safety and reliability of the experiment.

$ 2684.00

The highest temperature is 1400 ℃, the Furnace volume is 4.5L, and the aluminum oxide fiber Furnace and silicon carbon Rod heating elements are used to support the inert gas environment and ensure the uniform and stable sintering of the material.

$ 3720.00

Maximum temperature up to 1200 ℃, temperature control accuracy 1 ℃, with 30 program settings and over-temperature protection function, full range programmable automatic control of heating thermostatic, Furnace size 400 * 250 * 160mm.

$ 1272.00

Double shell structure with cold air system to achieve rapid cooling, 51 program temperature control system to ensure +/- 1 ℃ accuracy, the highest Operating temperature of 1700 ℃, corundum Furnace tube high temperature performance.

$ 4543.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.