Hand spray paint

Hand spray painting atomizes paint using compressed gas to spray out, forming a uniform coating. It is used for small area repairs and DIY painting, covering substrates such as metal and plastic.

Instruments

Hand type easy to operate, load 1000g, standard 6B-6H pencil, suitable for film hardness testing, test temperature 23 +/- 2 ℃ and Humidity 50 +/- 5% environment.

$ 341.00

Equipped with double spray guns to achieve uniform lame plating, the lifting range of the spray gun is adjustable from 10-500mm, the integrated air filtrate adjustment system supports magnetic or vacuum panel fixing, and improves the coating test Repeatability.

$ 67560.00

Adopt 0-3000rpm stepless speed regulation, Processing capacity 10-100L, with full explosion-proof structure and hand lifting system, suitable for dispersing and mixing of high viscosity materials.

$ 1661.00

Flow rate of spray 0-80CFM adjustable, spray distance 3-4 feet, visualize airflow direction and speed, support 30 minutes of continuous spray, easy flow and pressure equilibrate test.

$ 1703.00

Hand crank type is easy to operate, load 1000g +/- 1g, scratch speed about 1mm/s, test angle 45 °, standard 6B-6H pencil, in line with a number of international standards, through the pencil Hardness grade to accurately evaluate the scratch performance of the paint film.

$ 325.00

Adopt gear pair drive, hand-pressed operation, rated load 500N, Travel 70mm, the upper and lower height of the frame can be adjusted, Force Gauge has a positioning structure, suitable for batch testing.

$ 256.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

Adopt hand-crank mechanical pressurization method, Heating power 650W, Mold sleeve specification < 40mm, suitable for small or irregular samples, support thermosetting material inlay.

$ 649.00

Hand-crank mechanical pressurization is easy to operate, digital temperature controller to ensure stable temperature, Heating power 440W, mold sleeve specification < 25mm, suitable for thermosetting material inlay, protect the edge of the sample.

$ 517.00

Adopt gear pair transmission, hand-pressed operation, the height of the frame can be adjusted up and down, Force Gauge up and down movement is equipped with positioning structure, rated load 500N, Travel 70mm, suitable for batch testing.

$ 180.00

Rated load 500N, rack and pinion drive, hand pressure operation is simple and stable, large foot design to ensure smooth measurement process, Travel 75mm, suitable for Force Gauge installation for tensile or plug force test.

$ 181.00

It can measure the ability of the paint film to deform with the substrate without damage. It is equipped with a shaft Rod with a diaMeter of 50mm and 100mm.

$ 309.00

Hand pressure type is easy to operate, the rack and pinion transmission is smooth, the digital display ruler can display the displacement and lock the Travel, the maximum test load is 500N, the measurement Travel is 200mm, and the base is stable and the fuselage is heavy.

$ 248.00

The drying process of paint film and putty film can be accurately measured by using circular track needle design, equipped with four different radius needle (R0.25/0.5/1.0/1 mm), and the track period is 24h/r.

$ 223.00

Impact height of 120 cm, hammer mass 1000g, no secondary rebound phenomenon after impact, punch diaMeter 16mm, can accurately determine the impact strength of the paint film.

$ 370.00

Articles

Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Application of Automatic Film Coating Machines in the Preparation of Uniform Coatings in Laboratories
This article introduces the application of automatic film applicators in preparing uniform coatings in laboratories. Traditional manual coating methods are influenced by the operator's experience, making it difficult to ensure coating consistency.
Key Points for Controlling Coating Longitudinal Uniformity with Manual Rod Coater Constant Speed Dragging Techniques
This article discusses how to control the longitudinal uniformity of the coating by dragging at a constant speed when using a manual wire rod coater. A constant-speed drag is crucial, as it directly determines the consistency of the wet film thickness.
Film applicator standardized preparation of test samples.
The film applicator is a crucial tool in fields such as coatings and inks for preparing test samples, ensuring uniform thickness and a smooth surface through standardized operations. The article introduces its scraping-based working principle and the selection between manual and automatic types.
Standards and Equipment Selection for Drop Testing in Mobile Phone Whole-Machine Reliability Testing
Drop test is an important method to test the durability of mobile phones, simulating accidental drops in daily life to examine the impact resistance of components such as the casing and screen. The test must follow international or industry standards, specifying conditions such as drop height and number of times.
Selection Comparison between Automatic and Manual Proofing Methods for Ink Proofing Machines
This article compares manual and automatic proofing methods for ink proofing machines. Manual proofing relies on the operator's experience, offering flexibility and lower initial costs, but it suffers from poor consistency, making it suitable for research and development or low-frequency usage.
The softness tester can show a data difference of up to 30% when measuring paper hand-feel samples taken from different directions.
This article mainly discusses that when testing the softness of paper, if samples are taken along different directions, such as the machine direction (longitudinal) and the cross direction (transverse), the measured data can vary significantly, sometimes by as much as 30%.
Contact Angle Meter Selection Guide: How Can Laboratory Beginners Avoid Pitfalls?
The contact angle measuring instrument is used to analyze the wettability of solid surfaces and has applications in various fields such as materials and coatings. When selecting a model as a beginner, it is necessary to first understand key parameters such as static and dynamic contact angles and surface free energy, and then choose the configuration based on the specific application scenario.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.
How to Select a Pencil Hardness Tester? A Comprehensive Guide from Principles to Practical Application
When selecting a pencil hardness tester, focus on three key points: choose manual or automatic based on standards, use specialized testing pencils, and ensure the instrument can fix a 45-degree angle for uniform force application to achieve accurate and reliable results.