Multi-functional Tape Film Applicator

The multifunctional tape Coater transfers coating material evenly onto the substrate surface through rollers to form a coating of specified thickness. It is used for coating processing of materials such as tapes and labels, and for testing coating performance under simulated production conditions in the laboratory.

Instruments

16Mm large diaMeter is suitable for striped fabric and leather measurement, Repeatability Delta E * ab < 0.05, with multi-functional test components can measure liquid, powder and other samples to improve measurement accuracy.

$ 1897.00

Temperature range RT + 5~ 60 ℃, Oscillation Frequency 0~ 320rpm, support rotary and reciprocating oscillation mode, liner made of stainless steel corrosion resistance, stepless speed control smooth operation.

$ 883.00

Maximum pull-out force 40kN, using three-point reaction support and post-loading pull-out method principle, with color Touchscreen display force value and time Linear dispersion, support automatic storage of 10000 data.

$ 837.00

With 0~ 300rpm stepless speed regulation and 20mm swing amplitude, the multi-functional spring bottle test rack supports a variety of comparison experiments, and the low center of gravity of the whole machine ensures stable and reliable continuous work.

$ 298.00

Equipped with multi-functional test components to measure liquid and powder samples, 8mm measurement caliber to ensure accurate positioning, Repeatability fluctuation is less than 0.07 on average, light positioning function simplifies the operation process.

$ 1655.00

With a multi-functional spring bottle test rack, it supports a variety of comparative experiments; the stepless speed range is 0~ 250rpm, and the pendulum amplitude is 25mm; the center of gravity of the whole machine is low, and the continuous work is stable and reliable.

$ 364.00

Temperature control accuracy of +/- 1 ℃, Oscillation Frequency start~ 300rpm, with oxygen holes to ensure full oxygen, equipped with multi-functional spring bottle rack for a variety of comparative experiments, stepless speed control smooth operation and safety.

$ 503.00

The independent control of the dual temperature zone can simultaneously digest different paraMeters, the 30-hole design supports digestion capacity above 12mL, the temperature control accuracy is +/- 0.5 ° C, the temperature is raised to 165 ° C within 12 minutes, and the fully enclosed transparent protective cover ensures safety.

$ 1977.00

Adopt replica tape method to measure surface roughness, Peak Measurement range 20~ 115μm, accuracy +/- 5μm, with automatic subtracting substrate function, High Protection Rating, anti-solvent and water dust.

$ 935.00

Equipped with 10-station synchronous test capability, 1000g weight and 1-999999 minute Timer, using SUS #304 steel plate to ensure test accuracy, and automatically recording tape peeling time.

$ 748.00

Using 180 * 480mm size, with wire Rod or Film Applicator scraping ink, is conducive to the film flat and effective, improve film mass.

$ 122.00

Adopting 500 * 700mm Dimensions, used with bar or Film Applicator, is conducive to the smooth and effective film, and improves the convenience of film operation.

$ 227.00

The adhesive force of the tape is 4.3N/cm, and the principle of cross-cut method is adopted, which is suitable for adhesion testing. The performance is stable and non-degumming, and the test results are accurate and reliable.

$ 166.00

Hardness stainless steel material, Hardness of 50~ 55HRC, film accuracy +/- 2μm, smooth surface to support a variety of Spreader requirements, can be used with Film Applicator to achieve automatic film operation.

$ 162.00

Using a formed pRoduction process, the film Film thickness is as thin as 4.6μm, the accuracy is up to 0.1 micron, and the effective Spreader width is 30cm. It can be used with an automatic Film Applicator and has the advantage of continuous wire.

$ 186.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Using a spray coater to achieve the preparation of functionally graded films.
This paper introduces a method for preparing functionally gradient films using a spray coating machine.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.
Cross-cut tester combined with adhesion test tape for evaluating coating peel-off.
The cross-cut test, paired with adhesion test tape, is a commonly used method for evaluating coating adhesion. It involves using a cross-cut knife to score a grid pattern on the coating surface, followed by the rapid peeling of specialized tape. The adhesion level is then assessed by observing the extent of coating detachment.
Operation Tips for Laboratory-Scale Hot Melt Adhesive Coating Machines
This article introduces the key operational points of a laboratory-scale hot melt adhesive coater. The equipment is primarily used in laboratories to apply hot melt adhesives uniformly onto substrates, supporting the research, development, and testing of adhesives.
Standard Procedure for Cross-Cut Test of Ink Adhesion
The cross-cut test is a standard method for testing ink adhesion. It involves cutting a grid pattern on the coated surface, applying and then peeling off adhesive tape, and observing the extent of ink peeling to evaluate the adhesion grade.